Safety Analysis of a New Portable Electrical Drill With a Smart Autostop Mechanism for Bedside Cranial Procedures

Author:

Assumpcao de Monaco Bernardo,Benjamin Carolina Gesteira,Doomi Ahmed,Taylor Ruby,Stringfellow Cheyenne Elaina,Benveniste Ronald J.,Jagid Jonathan R.,Graciolli Cordeiro JoacirORCID

Abstract

BACKGROUND AND OBJECTIVES: Bedside procedures are often helpful for neurosurgical patients, especially in neurocritical care. Portable drills with technological advancements may bring more safety and efficiency to the bedside. In this study, we compared the safety and efficiency of a new cordless electric drill with smart autostop (“HD”—Hubly Cranial Drill, Hubly Surgical) with those of a well-established standard traditional electrical neurosurgical perforator (“ST”). METHODS: A cadaveric study was conducted using both drills to perform several burr holes in the fronto-temporo-parietal region of the skull. An evaluation was performed on the number of dura plunges, and complete burr hole success rates were compared. RESULTS: A total of 174 craniotomies using the HD and 36 burr holes using the ST perforator were performed. Despite significantly exceeding intended drill bit tolerance by multiple uses of a single-use disposable HD, autostop engaged in 100% of the 174 craniotomies and before violating dura in 99.4% of the 174 craniotomies, with the single dura penetration occurring on craniotomy no. 128 after the single-use drill bit had significantly dulled beyond its single-use tolerance. Autostop engaged before dura penetration for 100% of the 36 burr holes drilled with the ST perforator (P = .610). All the perforations were complete using the HD after resuming drilling. An autostop mechanism in a cranial drill is not commonly available for portable bedside perforators. In the operating room, most use a mechanical method to stop the rotation after losing bone resistance. This new drill uses an electrical mechanism (smart autostop) to stop drilling, making it a single-use cranial drill with advanced features for safety and efficiency at the bedside. CONCLUSION: There was no difference in the safety and efficacy of the new cordless electric drill with smart autostop when performing craniotomies compared with a traditional well-established electric cranial perforator with mechanical autostop on a cadaveric model.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Reference15 articles.

1. Cranial surgery dates back to Mesolithic;Lillie;Nature,1998

2. Minimally invasive bedside craniotomy using a self-controlling pre-adjustable mechanical twist drill trephine;Reinges;Surg Neurol,1998

3. Twist-drill craniostomy with hollow screws for evacuation of chronic subdural hematoma;Chari;J Neurosurg,2014

4. Burr hole hematoma evacuation of large subdural component using recombinant tissue-type plasminogen activator and a novel catheter: case report;Monaco;Cureus,2022

5. The torque and thrust force in twist drilling—I. Theory;Rubenstein;Int J Machine Tools Manufacture,1991

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献