The Effect of Locator Attachment and Ball-O-Ring Attachment on Bone Height Change in Implant Retained Overdenture

Author:

El Maroush Mohamed1,Eljayir Elmabrouk2,Ben Hamida Sarra1

Affiliation:

1. Department of Removable Prosthodontics, University of Tripoli, Tripoli, Libya.

2. Department of Removable Prosthodontics, Serit University, Serit, Libya.

Abstract

Objectives. This study was conducted to evaluate and compare the effect of locator attachment and Ball-O-ring attachment on the peri-implant crestal bone level changes in edentulous patients rehabilitated with implant retained lower over denture. Methods. Twenty edentulous patients (male) were participating in this study, they were rehabilitated by mucosa supported maxillary complete denture and implant retained mandibular over denture by two implants installed in the canine region, patients were divided into two equal groups according to the type of attachment used, the locator attachment was used for group I and Ball-O-ring attachment was used for group II. Peri-implant crestal bone level changes were assessed using intra-oral radiographs taken with the standardized long cone paralleling technique using custom made acrylic template and the Rinn-xcp system. Periapical radiographs were taken every six months to complete a period of 18 months follow up period. The marginal bone loss at different intervals was obtained by calculating the difference in bone height at that interval from the base line measurement and statistically analyzed (t-test P < 0.05). Results. The result of this study showed that the time has significant effect on the mean values of the peri-implant bone height on both groups. Moreover, group I had significantly less bone resorption from insertion to twelve months in compare to group II. Conclusion. The insignificant difference observed between comparing the peri-implant bone loss between the two groups indicates that the two treatment modalities are effective for the rehabilitation of lower denture. Locator attachments have the ability to control the amount bone loss. It could be advantageous in cases where the retention of implants retained overdentures is compromised.

Publisher

Faculty of Dentistry Khalij-Libya Dental College

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3