Study of State of Interface “Intraocular Lens — Posterior Capsule” Depending on Size of Capsulorhexis in Senile Cataract Phacoemulsification

Author:

Bai Lina1ORCID,Kolenko O. V.2ORCID,Egorova A. V.1ORCID,Vasiliev A. V.1ORCID

Affiliation:

1. Khabarovsk branch of the S. Fyodorov Eye Microsurgery Federal State Institution

2. Khabarovsk branch of the S. Fyodorov Eye Microsurgery Federal State Institution; Postgraduate Institute for Public Health Workers

Abstract

Purpose. To study the state of interface “intraocular lens (IOL) — posterior capsule (PC)” depending on diameter of capsulorhexis in phacoemulsification of senile cataract.Patients and methods. 227 patients (227 eyes) were examined after phacoemulsification of senile cataract at LenSx femtosecond laser (Alcon, USA). The study did not include patients with corneal opacities, signs of axial displacement of lens, with irido- and phacodonesis, glaucoma, axial length less than 22 mm and more than 26 mm. Depending on diameter of performed capsulorhexis, we formed 3 groups: 1st group — 76 eyes with diameter capsulorexis 5.5 mm; 2nd group — 73 eyes with 5.0 mm; 3rd group — 78 eyes with 4.5 mm. We studied type of interface “IOL — PC”, the maximum value of PC diastasis and the maximum depth of its folds using an RTVue-100 Optical Coherence Tomography (Optovue, USA) on the first day after the operation.Results. The maximum number of eyes with absence of contact between IOL and PC was noted in the 3rd group (62.8 %), the largest number of eyes with full contact between IOL and PC (63.2 %) was in the 1st group. The minimum average depth of the PC folds (111.1 ± 32.7 μm) was noted in the 1st group, and the maximum (165 ± 75.4 μm) — in the 2nd group.Conclusion. The analysis showed that type of interface “IOL — PC” in the first day after phacoemulsification of senile cataract depends on diameter of capsulorhexis. The largest number of eyes (64.6 %) with full contact between IOL and PC was observed in the group of patients with capsulorhexis 5.5 mm, and the smallest (6.4 %) — in eyes with diameter capsulorexis 4.5 mm. Presumably, the main reason for the absence or incomplete contact between IOL and PC is the presence of viscous dispersive between them. The deformation of PC in the form of folds does not directly depend on diameter of capsulorhexis and, obviously, is due to the uneven tension of the capsular bag by the IOL haptics.

Publisher

PE Polunina Elizareta Gennadievna

Subject

Ophthalmology

Reference20 articles.

1. Bai L., Vasiliev A.V., Egorova A.V. Clinical and functional results of IOL pneumocompression method implementation at phacoemulsification of senile cataract. Fyodorov Journal of Ophthalmic Surgery = Oftalmokhirurgiya. 2019;1:6–10 (In Russ.) DOI: 10.25276/0235-4160-2019-1-6-10

2. Vasiliev A.V., Egorova A.V., Egorov V.V., Bai L. Analysis of effectiveness of applying the IOL pneumocompression technique in phacoemulsification in prevention of posterior capsule opacification. Modern technologies in ophthalmology = Sovremennyye tekhnologii v oftal’mologii. 2017;6:32–34 (In Russ.)

3. Egorova E.V. Anatomical and topographical relations between the posterior lens capsule and the intraocular lens in pseudo-exfoliation syndrome. Ophthalmology in Russia = Oftalmologiya. 2018;15(2S):134–139 (In Russ.) DOI: 10.18008/1816-5095-2018-2S-134-139

4. Hirnschall N., Nishi Y., Crnej A., Koshy J., Gangwani V., Maurino V., Findl O. Capsular bag stability and posterior capsule opacification of a plate-haptic design micro incision cataract surgery intraocular lens: 3-year results of a randomized trial. Br. J. Ophthalmol. 2013;97(12):1565–1568. DOI: 10.1136/bjophthalmol-2013-303710

5. Lytvynchuk L.M., Glittenberg C.G., Falkner-Radler C.I., Neumaier-Ammerer B., Smretschnig E., Hagen S., Ansari-Shahrezaei S., Binder S. Evaluation of intraocular lens position during phacoemulsification using intraoperative spectral-domain optical coherence tomography. J. Cataract. Refract. Surg. 2016;42(5):694–702. DOI: 10.1016/j.jcrs.2016.01.044

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3