New experiments upon the combustion of well-dried carbon monoxide and oxygen mixtures.—Part II

Author:

Abstract

For this third series of experiments a special form of apparatus (shown diagrammatically “in plan” in fig. 1) was set up, whereby the ignitibilities of 2CO + O 2 mixtures, whose components had been thoroughly dried (after compression) over re-distilled phosphoric anhydride in small steel cylinders, could be tested in a nickel-steel bomb with a 1-in. diameter cylindrical explosion chamber at various initial pressures up to 20 atmospheres. The whole system and its connections had been previously thoroughly dried out by continuously circulating P 2 O 5 -dried nitrogen round it day and night for several months together. The following is a detailed description of the apparatus :— Apparatus . The nickel-steel cylindrical bomb A* (with explosion chamber 8 inches long by 1 inch diameter, capacity 103 c. c.) was clamped horizontally to a special iron casting, which permitted of the bomb being rocked as and when required. This was bolted down to the experimental table, on to which were also fixed all the other items of the installation. The outside of the bomb, whose overall dimensions were 16 inches by 5 inches diameter, was wound with nichrome wire, so that it could be heated electrically to a temperature of 150° C. or more to facilitate the drying of it. It was fitted with a specially designed firing plug P, consisting of a central electrode (5 inches long by 1/8 inch diameter nickel-steel rod), which was wrapped round with an insulating packing of compressed mica to a thickness of 5/16 inch, in such a manner as to make a perfectly gastight joint even at high explosion pressures. It should be particularly noted that no organic substance whatever was employed in “packing” the firing piece, or indeed in any other part of the bomb or apparatus. The electrode of the firing piece projected about 3½ inches out of the body of the bomb in order to allow of a sufficiently high voltage being applied when a mixture had to be fired under high pressure. The bomb was closed at each end by the high-pressure steel valves V 1 and V 2 , respectively.

Publisher

The Royal Society

Subject

General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3