Adoption of Color Doppler Ultrasound in the Measurement of Fetal Hypoxia in Late Pregnancy

Author:

Wu Wenying,Zhao Li,Feng Peiming,Wang Xiaoyan,Nie Minghui

Abstract

Objective: In order to improve the detection rate of fetal hypoxia in the third trimester and reduce the probability of adverse pregnancy outcome, color doppler ultrasound (CDU), and contractions were used to assess the severity of fetal hypoxia. Methods: The 61 pregnant women diagnosed with intrauterine hypoxia in South District of The Affiliated Hospital of Chengde Medical College from October 2017 to September 2019 were classified as the sick group. Meanwhile, the 61 normal pregnant women were selected as the control group. CDU was used to detect the relevant indexes of umbilical artery (UA) and middle cerebral artery (MCA) in the two groups, including pulse index (PI), resistance index (RI), systolic peak blood flow velocity (S) and diastolic peak blood flow velocity (D). The Apgar scale was used to score neonatal status. According to the score results, newborns were divided into Apgar ≤ 7 group and Apgar > 7 group. The indexes of UA and MCA were compared between the two groups. The amniotic fluid status of pregnant women was assessed using the contractile stimulation test (CST). The rate of amniotic fluid pollution in pregnant women and the incidence of neonatal asphyxia were calculated. Pregnant women were grouped according to the CST score. The correlation between CST score and amniotic fluid pollution and neonatal asphyxia in pregnant women was analyzed. Results: First, the index of fetal UA was obviously higher than that of the control group, while the index of MCA was obviously lower than that of the control group (P < 0.05). Second, the indexes of fetal UA in Apgar ≤ 7 group were obviously higher than those in Apgar > 7 group, while those in MCA were obviously lower than those in Apgar > 7 group (P < 0.05). Third, the incidence of amniotic fluid pollution and neonatal asphyxia in low and middle groups of pregnant women was obviously higher than that in high groups (P < 0.01). Conclusion: This indicates that the CDU technology combined with uterine contraction stimulation experiment can assess the degree of intrauterine hypoxia in the late stage of pregnancy, which provides a feasible scheme for clinical detection of intrauterine hypoxia.

Publisher

American Scientific Publishers

Subject

Health Informatics,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3