Abstract
Introduction. Intra-laboratory comparison tests play an important role in ensuring the quality and reliability of research outcomes in laboratories. These tests allow researchers to evaluate the accuracy and reproducibility of the methods they use in their work, as well as to identify potential sources of error and inconsistency. The results of these tests are shared with experts to confirm competence within the accreditation. Typically, comparison tests are carried out in laboratory conditions in a familiar and calm environment for the testers. However, when laboratories conduct research as part of a special assessment of working conditions (SAWC) they are required to conduct on-site comparisons at real-world facilities, where customers may unwittingly disrupt the process and directly affecting the quality of the measurements. The aim of this study is to evaluate the quality of on-site intra-laboratory comparison tests using the example of determining the dust content in a bricklayer's work environment on a construction site, and to determine the minimum number of measurements necessary and sufficient for this purpose.Materials and Methods. To determine the dustiness of the bricklayer's workplace, a weighing method was used. This involved collecting dust on filters and then weighing them to determine the concentration. The quality assessment of intra-laboratory tests was conducted in accordance with GOST R ISO 5725-1-2002 "Accuracy (trueness and precision) of measurement methods and results. Part 1. General principles and definitions".Results. At the bricklayer's workplace, a 1.6-fold excess of the one-time maximum permissible dust concentration was detected. The average dust concentration at the workplace under study was: Kp2 = 9.57 ± 0.81 mg/m3, the convergence of the results obtained was r = 8.68 %, the relative error δ = 8.50 %. It was revealed that the maximum allowable difference between the results of the two tests was 0.84 mg/m3. The difference in direct measurements of the mass of the two samples should be no more than 0.1 mg.Discussion and Conclusion. The results obtained demonstrated the possibility of conducting a minimum number of measurements that, under reproducible conditions, are considered satisfactory and could be provided to experts for confirming the competence of the laboratory. As part of a special assessment of working conditions, employees of the object under study are recommended to use personal respiratory protection equipment that offers protection against highly dispersed dust particles.
Publisher
FSFEI HE Don State Technical University
Reference19 articles.
1. Kuchergin NI. SOUT — spetsial'naya otsenka uslovii truda. Studencheskii forum. 2022;44–1(223):6–7. URL: https://nauchforum.ru/archive/studjournal/44%28223_1%29.pdf (accessed: 08.11.2023). (In Russ.).
2. Panteleeva OV, Yakovenko OV. SOUT kak kontrol' kachestva bezopasnosti. In: Trudy II Vserossiiskoi nauchno- tekhnicheskoi konferentsii "Sovremennye problemy ekologii i promyshlennoi bezopasnosti". Novocherkassk: Platov South-Russian State Polytechnic University (NPI); 2023. P. 97–100. (In Russ.).
3. Gasilina T. Novshestva v zakonodatel'stve po SOUT. TekhNadzor. 2017;1–2(122–123):47–48. (In Russ.).
4. Mamytov EG. Normativno-pravovye novatsii po ispol'zovaniyu rezul'tatov SOUT. Standards and Quality. 2015;2:82–83. (In Russ.).
5. Pakhomova LA, Oleinik PP. Selection and evaluation of work place certification parameters (special assessment of labor conditions). Construction production. 2019;1:49–52. https://doi.org/10.54950/26585340_2019_1_49 (In Russ.).