Fire Resistance of a Building Element with Intumescent Fire Protection: Standard Assessment and Express Analysis

Author:

Martynov A. V.1ORCID,Grekov V. V.1ORCID,Popova O. V.2ORCID

Affiliation:

1. Don State Technical University

2. Stroitel'stvo Kachestvo Bezopasnost' OOO

Abstract

Introduction. The paper considers the problem of fire resistance assessment of building structures with intumescent fire protection. For the results reliability, a fire test should be carried out only when the intumescent coating at the facility is ready, which will make it possible to detect hidden factors of violation of its quality and prevent collapse in case of a possible fire. The work objective is to test the express analysis of intumescent coatings in comparison with standard methods for fire resistance assessment.Materials and Methods. The elements of building structures covered with fire-resistant intumescent paint Defender M Solvent with different diluent content were studied. The fire resistance of the coatings was determined by two methods. The first one is an express analysis. The following indicators were recorded:– general appearance of the coked cellular material (CCM);– swelling coefficient;– CCM compressive and shear-tear strength of the boundary layer.The second one is a standard approach according to the requirements of ISO 834-75 (GOST 30247.0-94). The indicators were:– time to reach the critical temperature;– critical deflection during heating.Results. In addition to the above indicators, testing also took into account the amount of diluent. The CCM swelling coefficient, CCM compression force, tensile strength and density were considered. The revealed patterns are systematized in a table. The obtained indicators were compared with the technical requirements for the material. The period during which the steel substrate of the sample reaches a critical temperature is recorded. It is established that with an increase in this time, the coefficient of swelling of the protective layer (CCM) and its shear-tear strength increases. At the same time, the values of compressive strength and CCM density decrease. When the intumescent paint is diluted beyond the norm, the fire protection parameters deteriorate and the fire resistance limit R45 is not reached. The research results are visualized in the form of diagrams. They confirm that the express analysis makes it possible to reasonably judge the suitability or unsuitability of the paint for fire protection, if the required fire resistance limit is R45.Discussion and Conclusions. In comparison with the results of the application of standard techniques, the effectiveness of the express analysis technique and the correctness of the results of the assessment of intumescent fire protection were confirmed. In construction conditions, an express CCM analysis will be sufficient to determine the quality of an intumescent fire retardant coating.

Publisher

FSFEI HE Don State Technical University

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3