Comparision of <sup>11</sup>C-methionine and <sup>11</sup>C-choline pet/ct for parathyroid visualization: a prospective study

Author:

Pogosian K. А.1ORCID,Karonova T. L.1ORCID,Ryzhkova D. V.1ORCID,Yanevskaya L. G.1ORCID,Boriskova M. E.2ORCID,Zuykevich D. V.2ORCID,Yudina O. V.1,Tsoy U. A.1ORCID,Grineva E. N.1ORCID

Affiliation:

1. Almazov National Medical Research Centre, World-Class Research Centre for Personalized Medicine

2. Pavlov First Saint Petersburg State Medical University

Abstract

INTRODUCTION: Primary hyperparathyroidism (PHPT) is a common endocrine disorder. Minimal invasive parathyroidectomy (PTX) is favorable surgical approach in PHPT treatment. Its success is highly dependent on accurate preoperative localization of all causative parathyroid adenomas. Despite the fact that wide range of visualization methods are applied in PHPT diagnostics, PHPT persistence occurs. Therefore, the search for additional visualizing tools of parathyroid adenomas remains relevant. Recently, positron emission tomography/computed tomography (PET/CT) has been used in order to improve PHPT diagnostics. OBJECTIVE: To evaluate the diagnostic effectiveness of PET/CT with 11C-methionine and 11C-choline in patients with PHPT based on the intensity of both tracers uptake in parathyroid adenomas. MATERIALS AND METHODS: The data of 26 patients diagnosed with PHPT was analyzed. PET/CT with 11C-choline was performed in 14 patients, with 11C-methionine — in 10 patients, with two radiopharmaceuticals — in two patients. All patients underwent PTX. Histological examination’s results were compared with the results of PET/CT. Using the software, the standardized uptake value of radiopharmaceuticals in histologically verified parathyroid adenomas/hyperplasias and in the trapezius muscle was obtained, then tumor-to-background ratios (TBR) of 11C-methionine and 11C-choline were calculated.Statistics: Software STATISTICA 10 was used in statistical analysis.RESULTS: 11C-choline TBR median was of 2.3 (1.6; 3.2), median of 11C-methionine TBR showed slightly higher values — 2.5 (1.9; 3,6). However, no significant difference was found between the two radiopharmaceuticals’ uptake in parathyroid adenomas.DISCUSSION: The scientific impact of current study is determined by the diagnostic effectiveness comparison between PET/CT with 11C-methionine and 11C-choline, which is based on the accumulation intensity of both radiopharmaceuticals in parathyroid adenomas.CONCLUSION: The intensity of accumulation of 11C-methionine and 11C-choline by hyperfunctioning parathyroid tissue does not differ significantly. Thus both tracers might be successfully applied for topic diagnosis of parathyroid adenomas in patients with PHPT.

Publisher

Baltic Medical Education Center

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司