Does Proteinuria Measured by Dipstick Method Reflect Reality in Patients with Preeclampsia?

Author:

Soysal Cenk1ORCID,Işıkalan Mehmet Murat2ORCID

Affiliation:

1. KÜTAHYA SAĞLIK BİLİMLERİ ÜNİVERSİTESİ, TIP FAKÜLTESİ

2. BAŞKENT ÜNİVERSİTESİ, TIP FAKÜLTESİ

Abstract

Aim: The aim of our study is to compare the proteinuria levels measured by dipstick in complete urine analysis at admission with the proteinuria levels measured in 24-hour collected urine for patients hospitalized with a presumptive diagnosis of preeclampsia. By doing so, we intend to review the reliability of the widely used dipstick proteinuria in patients with preeclampsia. Material ve Metod: Urine specimens were obtained from 70 pregnant women visiting high-risk maternity centers at a third-level healthcare institution. Patients were divided into four groups based on their urine dipstick screening test results: negative, +1, +2, +3, and higher. Proteinuria was considered to be present if the urinary dipstick test showed +1 or higher, while protein levels measured in the 24-hour urine collection were considered to indicate proteinuria if they exceeded 300 mg. The degree of correlation between the urine dipstick test and both 24-hour urine samples and spot urine protein-to-creatinine ratio (Pr/Cr) was compared. Results: The mean age of the 70 preeclampsia patients in the study group was 31.7±6.2, and the mean gestational age was 32.5±4.6. The dipstick test was found to have a sensitivity of 81.4% and a specificity of 85.2%. The dipstick test results were grouped as 0, +1, +2, +3, and higher. Statistically significant differences were detected among the groups in terms of systolic blood pressure, diastolic blood pressure, the amount of protein in the 24-hour urine, and spot urine Pr/Cr (p=0.001, p<0.001, p<0.001, p<0.001, respectively). When examining the correlation between the urine dipstick test and both 24-hour urine samples and spot urine Pr/Cr, a moderate correlation was found (r=0.65, p<0.001, r=0.55, p<0.001, respectively). Conclusion: In hypertensive pregnant individuals, urine dipstick tests demonstrated inadequate performance in ruling out preeclampsia. Consequently, according to our investigation, we posit that the dipstick urine test can be employed as a routine and dependable diagnostic tool for preeclampsia due to its rapid results and cost-effectiveness.

Publisher

Selcuk University

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3