IgM and IgA Antibody Responses in 12 Cases of Human Acquired Toxoplasmosis

Author:

TAKAHASHI Emília E. H.,ROSSI Cláudio L.1

Affiliation:

1. Universidade Estadual de Campinas

Abstract

The persistence, in some subjects, of specific IgM antibodies to Toxoplasma gondii for several months after the acute phase of infection has complicated the interpretation of serological test results for toxoplasmosis. Several reports have emphasized the value of the detection of Toxoplasma-specific IgA antibodies for the diagnosis of acute toxoplasmosis. In this article, we report the follow-up profiles of Toxoplasma-specific IgM and IgA antibodies in serum samples obtained from 12 patients at various intervals after the onset of the clinical manifestations of infection. IgM antibodies were detected by the indirect immunofluorescence (IIF) test, antibody capture enzyme-linked immunosorbent assay (cELISA) and enzyme-mediated chemilluminescent technique (CmL). IgA antibodies were quantified by the direct ELISA (dELISA) and cELISA procedures. As defined by the manufacturer of the cELISA test for IgA used, most patients with acute toxoplasmosis have antibody levels > 40 arbritary units per ml (AU/ml). At values > 40 AU/ml, the cELISA for IgA detected significant antibody levels for a shorter time than the other techniques used for IgM and IgA detection. However, IgA levels <FONT FACE="Symbol">£</font> 40 AU/ml do not exclude the possibility of acute toxoplasmosis since such levels can be reached very soon after infection with T. gondii. The results obtained in the present study show that the serological diagnosis of acute toxoplasmosis may not be such an easy task. Our data suggest that use of the IgA-cELISA concomitantly with IgM antibody screening could permit, in some circumstances, a more efficient diagnosis of acute acquired toxoplasmosis

Publisher

FapUNIFESP (SciELO)

Subject

Infectious Diseases,General Medicine

Reference27 articles.

1. False-positive anti-Toxoplasma fluorescent-antibody tests in patients with antinuclear antibodies;ARAUJO F. G.;Appl. Microbiol.,1971

2. Comparison of relative uses of commercial assays for Toxoplasma gondii IgM antibodies;ASHBURN D.;J. clin. Path.,1992

3. IgA antibody response during acquired and congenital toxoplasmosis;BESSIÈRES M. H.;J. clin. Path.,1992

4. High levels of IgM antibodies specific for Toxoplasma gondii in pregnancy 12 years after primary Toxoplasma infection;BOBIC B.;Gynec. Obstet. Invest.,1991

5. Rheumatoid factors as a cause for false-positive IgM anti-Toxoplasma fluorescent tests: A technique for specific results;CAMARGO M. E.;Rev. Inst. Med. trop. S. Paulo,1972

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献