Affiliation:
1. Universidade do Vale do Rio dos Sinos, Brasil
2. Universidade de Coimbra, Portugal
Abstract
Abstract Composite steel decking concrete slabs are an important structural member in building construction. Research on its thermal behavior should be developed to understand its fire performance. In this paper, a comparison of the temperature distribution in the cross-section of steel decking concrete slabs subjected to fire is made through three different procedures: (a) standardized analytical, (b) experimental and (c) numerical. The analytical method was the one proposed in NBR 14323 standard. The experimental tests corresponding to eight real-scale fire tests on composite slabs carried out by the authors. The numerical tests were done for the same configurations of the experimental tests and used the FEA software Abaqus. Steel decking temperatures obtained with NBR 14323 methodologies showed good convergence with the experimental and numerical ones. The same was not observed for the concrete, positive and negative rebar.
Reference40 articles.
1. Review of the high temperature mechanical and thermal properties of the steels used in cold formed steel structures - The case of the S280GD+Z steel;Craveiro H. D.;Thin-walled Struct.,2016
2. Advanced modeling of composite slabs with thin-walled steel sheeting submitted to fire;Pantousa D.;Fire Technol.,2013
3. Design of Composite Steel and Concrete Structures. Part 1.2 - Design Rules, Structural Fire Design, EN 1994-1-2,2011
4. Fire Resistance Tests - Elements of Building Construction, ISO 834-8,1999
5. The fire resistance of composite steel-concrete slabs;Both C.,1998
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献