Author:
Jackson W. B.,Johnson N. M.,Walker J.
Abstract
ABSTRACTMeasurement of the dependence of emission capacitance transients on filling pulse duration has been extended to devices with Ohmic back contacts. Capacitance transients on devices possessing identical bulk 20-ppm P doped a-Si:H but either Ohmic contacts or blocking contacts were compared. The devices with blocking contacts completely reproduced in quantitative detail the previously observed anomalous dependence of capacitance transients on filling pulse duration. The diodes with Ohmic contacts showed no evidence of the anomalous filling pulse effect even for light-degraded, resistive samples. Current injection measurements show that blocking contacts delay the charge injection into the device by about 10–100 msec.
Publisher
Springer Science and Business Media LLC
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献