Author:
Kilgore Steve,Gaw Craig,Henry Haldane,Hill Darrell,Schroder Dieter
Abstract
AbstractElectromigration tests were performed on passivated electroplated Au four terminal Kelvin line structures using the conventional in situ resistance monitoring technique. The stress conditions were a current density of 2.0 MA/cm2 with ambient temperatures ranging from 325°C to 375°C. The temperature coefficients of resistance (TCR) values were measured prior to current stressing to calculate the Joule heated film temperatures. The times to failure (lifetimes) for the Au line structures were considered as a 50% ΔR/R0 change. The median time to failure (t50%) was plotted against the inverse film temperature to determine the activation energy value as 0.59 ± 0.09 eV. Failure analysis of void location and suggested diffusion mechanism will be discussed.
Publisher
Springer Science and Business Media LLC
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献