Author:
Mccolgin William C.,Lavine James P.,Stancampiano Charles V.
Abstract
AbstractDark current spectroscopy (DCS) is used to identify the signature of metals that generate dark or leakage current in silicon image sensors. Individual metal atoms or defects are detected by DCS on a pixel-by-pixel basis. DCS is applied here to show how the number of electrically active iron atoms in a pixel changes with light and with low-temperature anneals. The measurements explore the dissociation and association of iron-boron pairs and the diffusion of iron near room temperature.
Publisher
Springer Science and Business Media LLC
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献