Effect of Nebulised Lignocaine on the Quality of I-gel Insertion: A Randomised Controlled Trial

Author:

Sannaboraiah Sushma K,Pushpavathi HS,Yashaswini KL

Abstract

Introduction: Supraglottic Airway Devices (SAD) are integral part of airway management during General Anaesthesia (GA) and are less invasive than endotracheal intubation. I-gel is a novel and innovative SAD, with non inflating cuff and it is widely used among available devices. Various drug combinations are being studied to obtain better insertion conditions. Lignocaine nebulisation is popularly used as topical anaesthesia for the airway. Authors hypothesised that it could improve the insertion conditions of the airway in addition to induction agents. Aim: To assess the efficacy of lignocaine nebulisation for I-gel insertion conditions in terms of the frequency of optimal insertion conditions and haemodynamic changes observed during and after the insertion of I-gel. Materials and Methods: This randomised controlled trial was conducted for one year from January 2019 to January 2020 in Karnataka Institute of Medical sciences, Hubli, Karnataka, India. Ninety patients of age group 18 to 45 years, belonging to American Society of Anaesthesiologists’ (ASA) grade I and II, undergoing minor surgical procedures were included. They were randomised into two equal groups, group L received 5 mL of 4% lignocaine and group D received 5 mL of normal saline nebulisation 5 minutes before induction of GA. Optimal insertion conditions (successful insertion at the first attempt without adverse response) and haemodynamic responses were noted down as primary and secondary outcomes respectively. The data was analysed using Chi-square test and Student’s t-test according to parameters. Results: A total of 43 patients were in group lignocaine nebulisation (Group L) and 44 in the normal saline nebulisation group (Group D) and they had the mean age of 28.8±6.3 and 29.0±5.1 respectively. The optimal insertion (p-value 0.26), successful first attempt insertion (p-value 0.175) and time for insertion (p-value 0.512) were not statistically significant between the two groups. In group L at 1 and 5 minutes, fall in Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP) was noted and compared with other group which was not statistically significant. Conclusion: Preinduction lignocaine nebulisation doesn’t improve optimal insertion conditions of I-gel statistically. Even though better haemodynamic were noted with the same, it cannot be recommended for the sole purpose by nebulisation route.

Publisher

JCDR Research and Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3