Efficacy of Two Paediatric Rotary Systems: Kedo-SG Blue™ and Prime Pedo™ Files in Primary Mandibular Molars: A Randomised Clinical Trial

Author:

Jeepalyam Saranya,Nirmala SVSG,Nuvvula Sivakumar

Abstract

Introduction: The success of root canal procedures depends on cleaning and shaping of canals. There are several instrumentation techniques available for root canal preparation. Recently, exclusive rotary file systems called Kedo-SG Blue and Prime-Pedo have been introduced for root canal preparation in primary teeth. The inherent flexibility of these files allows them to preserve the anatomy of curved canals in primary molars. Aim: To compare the instrumentation time, obturation time, and quality of obturation using two paediatric rotary file systems, KedoSG BlueTM and Prime-PedoTM, in mandibular primary molars. Materials and Methods: A randomised clinical trial was conducted in the outpatient Department of Paediatric and Preventive Dentistry, Narayana Dental College and Hospital, Nellore Andhra Pradesh, India, from February 1, 2019 to January 20, 2020. Fifty primary molars with necrotic pulp were included and randomly divided into two groups, with 25 teeth in each group. Group 1 and Group 2 were instrumented with Kedo-SG BlueTM and Prime-PedoTM, respectively. The time taken for instrumentation and obturation was noted in minutes, and the quality of root canal filling was recorded as optimal, underfilled, or overfilled. The data were statistically analysed using an independent Student’s t-test for time measurements and a Chi-square test for the quality of obturation. Results: There was a statistically significant difference in instrumentation time and obturation time between the two groups (p-value=0.009; 0.011). The Kedo-SG BlueTM rotary system showed a better quality of obturation compared to the Prime-PedoTM rotary system, although the difference was not statistically significant (p-value=0.22). Conclusion: The Kedo-SG BlueTM rotary system demonstrated shorter instrumentation and obturation times, as well as a higher number of optimally filled canals compared to the Prime-PedoTM rotary system. Therefore, the Kedo-SG BlueTM rotary system exhibited better clinical performance in primary molars than the Prime-PedoTM rotary system.

Publisher

JCDR Research and Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3