Repeatability of Corneal Aberrations and Ocular Biometry Measurements Using the Pentacam® AXL: A Cross-sectional Study

Author:

Almutairi Meznah S,Altoaimi Basal H,Fahmy Rania,Algowaifly Shatha I,Alenazi May S

Abstract

Introduction: Accurate assessment of ocular biometry and corneal aberrations for diagnosis and therapy is crucial in many clinical settings. Devices to improve the measurements of these parameters are constantly being developed. Aim: To evaluate the repeatability of ocular biometry and corneal aberrations obtained by the Pentacam® AXL in normal eyes. Materials and Methods: This cross-sectional study was conducted in the Optometry Department of King Saud Universiy, Riyadh, Saudi Arabia from September 2021 to February 2022. The study included a total of 120 eyes from 60 normally sighted adult participants whose of ocular biometry and corneal aberrations were measured three times in a single session using the Pentacam® AXL. Biometric parameters include Axial Length (AL), mean K-reading (Km), Anterior Chamber Depth (ACD), Central Corneal Thickness (CCT), and Horizontal White-toWhite Distance (HWTW). The aberrometry parameters include the most significant corneal higher-order aberrations (coma, trefoil, spherical aberration), and the Root Mean Square (RMS) of the higher-order aberrations. Repeatability was assessed using within-subject Standard Deviation (SDw), the repeatability limit (r), and the Intraclass Correlation Coefficient (ICC). Results: The current study included 120 eyes of 60 subjects with a mean age of 21±2.08 years (range: 18 to 28 years). The repeatability was good for all recorded biometric measurements, with the most repeatable being AL (r=0.028, SD=0.01). All values of ICC for biometric measurements revealed excellent repeatability, being over 0.994. In addition, coma and spherical aberrations had excellent repeatability with ICC ≥0.935, and RMS, trefoil, secondary astigmatism, and quadrafoil aberrations had good repeatability with ICC 0.938, 0.823, 0.898, and 0.827, respectively. Conclusion: The Pentacam® AXL demonstrated good repeatability for ocular biometry and corneal aberrations in healthy eyes.

Publisher

JCDR Research and Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3