Association of results of the glutaraldehyde coagulation test with plasma acute phase protein concentrations and hematologic findings in hospitalized cows

Author:

Trefz Florian M.,Balmer Martina,Peters Laureen M.,Bruckmaier Rupert M.,Meylan Mireille

Abstract

IntroductionThe glutaraldehyde test (GAT) allows for animal-side semi-quantitative estimation of fibrinogen and gamma-globulin concentrations in blood samples of adult cattle and therefore detection of inflammatory disease conditions. However, the test has potential limitations, especially due to the latency period until sufficiently high fibrinogen and/or gamma-globulin concentrations are reached. The aim of the present study was therefore to assess the association between results of GAT with other inflammatory markers including hematologic variables, fibrinogen, plasma haptoglobin and serum amyloid A (SAA) concentrations.MethodsFor the purpose of this prospective observational study, a convenience sample of 202 cows with a broad range of inflammatory and non-inflammatory clinical conditions was included. The GAT was run on EDTA blood, fibrinogen was measured using the Clauss and the heat precipitation method, and commercially available ELISA tests were used for determination of plasma haptoglobin and SAA concentrations.ResultsShortened GAT coagulation times were more closely correlated to serum globulin (rs = −0.72) than to plasma fibrinogen concentrations measured with the heat precipitation (rs = −0.64) and the Clauss method (rs = −0.70). Cows with a markedly (≤3 min) or moderately (4–6 min) shortened coagulation time had higher (p < 0.001) plasma haptoglobin and SAA concentrations than cows with a negative test result. Total leukocyte, monocyte and neutrophil concentrations did not differ significantly between groups. An identified cut-off for the GAT coagulation time of ≤14 min had a sensitivity and specificity of 54.4 and 100%, respectively, for the prediction of an inflammatory state based on clinical findings and/or increased plasma haptoglobin or SAA concentrations.DiscussionIn conclusion, this study demonstrates considerable diagnostic agreement between positive GAT results and increased plasma concentrations of haptoglobin and SAA. Despite high specificity, the test lacks sensitivity in case of acute inflammatory conditions indicating that plasma acute phase protein concentrations and hematologic findings can provide additional diagnostic information if the GAT is negative.

Publisher

Frontiers Media SA

Reference60 articles.

1. A preliminary report of a rapid method for the demonstration of abnormal gammaglobulin levels in bovine whole blood;Sandholm;Res Vet Sci,1974

2. Die Feststellung der Hyper-γ-Globulinämie beim Rind unter Praxisbedingungen;Sandholm;Tierärztl Prax,1974

3. The value of the glutaraldehyde and formaldehyde tests in evaluation of the globulin level in bovine blood;Liberg;Acta Vet Scand,1975

4. Application of the glutaraldehyde test in cattle;Metzner;J Vet Med A Physiol Pathol Clin Med,2007

5. Utilization of the glutaraldehyde coagulation test in cattle;Kováč;Acta Vet Brno,2014

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3