Ultrasound flow phantom for transcranial Doppler: An assessment of angular mismatch effect on blood velocity measurement in comparison to optical particle image velocimetry

Author:

Hashuro Muhammad Shiddiq Sayyid,Daibo Kotaro,Ishii Takuro,Saijo Yoshifumi,Ohta Makoto

Abstract

Detecting abnormal blood flow is possible through transcranial Doppler (TCD) ultrasound by measuring blood velocity in cerebral arteries. Velocity measurements are at the highest precision when the direction of blood flow coincides with the ultrasound beam. However, because TCD is typically performed blindly (i.e., without a B-mode), a 0° interrogation angle is usually assumed. This leads to a common issue of angular mismatch. This study quantitatively shows the angular mismatch effects on the measured velocities using a TCD ultrasound flow phantom compared with the velocities measured by optical particle image velocimetry (PIV) as control. Resulting errors with and without ultrasound machine angular correction were also considered. An ultrasound phantom developed by combining polyvinyl alcohol hydrogel (PVA-H), quartz glass as a scatterer, and a gypsum plate as a skull bone was utilized to approximate the middle cerebral artery TCD measurement from the temporal window. The PVA-H and quartz glass compositions were controlled to achieve transparency and enable PIV velocity measurement. Then, TCD velocity measurement was conducted on several interrogation and mismatch angles. Comparison results revealed that without an ultrasound machine angle correction, all measurements yielded underestimation with 73.9% at the highest in the 80° interrogation window at the 130 mL/min flow. On the other hand, with the correction, the errors in almost all angles were comparatively lower; however, at 80° at the 124 mL/min flow, a maximum overestimation rate of 113.7% was found, showing a larger error magnitude. Therefore, we find that angular mismatch, especially in larger angles, leads to inaccurate velocity measurements in TCD. Our results suggest that despite angle correction, velocity errors may still occur when the interrogation angle changes.

Publisher

Frontiers Media SA

Subject

Physical and Theoretical Chemistry,General Physics and Astronomy,Mathematical Physics,Materials Science (miscellaneous),Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3