Author:
Bianco Blandine,François-Garret Bérengère,Butin Marine,Dalmasso Cyril,Casagrande Florence,Mokhtari Mostafa,Eleni Dit Trolli Sergio
Abstract
Objectives: To evaluate the positive threshold of PCT for neonates of <32 weeks of gestation for the diagnosis of early-onset sepsis and to determine if the level of PCT collected within 6 h of life could be used.Design: Retrospective and bicentric study from May 2016 to April 2018.Setting: Two groups were established, neonates evaluated for PCT at birth (CordPCT) and within 6 h of life (delPCT).Patients: Two hundred and sixty neonates of <32 weeks of gestation born in Nice and South Paris (Bicêtre) University Hospitals, had been evaluated for PCT level.Main Outcomes Measures: The value of the PCT positive threshold was determined for the total population and each groups thanks ROC curves.Results: The threshold level of PCT for the total population was 0.98 ng/mL. The threshold value of cordPCT group was 1.00 vs. 0.98 ng/mL for delPCT group. The area under the Receiver Operating Characteristics curve for PCT sampled in delPCT group was significantly higher than in cordPCT group (0.94 compared to 0.75).Conclusions: The threshold level of PCT was higher in this cohort of neonates of <32 weeks of gestation compared to the value generally described for term neonates. The secondary sampling PCT level seems to be usable in screening algorithm for early-onset neonatal sepsis.
Subject
Pediatrics, Perinatology, and Child Health
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献