Cost-Effectiveness of Point-of-Care A1C Tests in a Primary Care Setting

Author:

Rosa Lorena de Sousa,Mistro Sóstenes,Oliveira Marcio Galvão,Kochergin Clavdia Nickolaevna,Cortes Mateus Lopes,Medeiros Danielle Souto de,Soares Daniela Arruda,Louzado José Andrade,Silva Kelle Oliveira,Bezerra Vanessa Moraes,Amorim Welma Wildes,Barone Mark,Passos Luiz Carlos

Abstract

Objective: We evaluated the cost-effectiveness of the point-of-care A1c (POC-A1c) test device vs. the traditional laboratory dosage in a primary care setting for people living with type 2 diabetes.Materials and Methods: The Markov model with a 10-year time horizon was based on data from the HealthRise project, in which a group of interventions was implemented to improve diabetes and hypertension control in the primary care network of the urban area of a Brazilian municipality. A POC-A1c device was provided to be used directly in a primary care unit, and for a period of 18 months, 288 patients were included in the point-of-care group, and 1,102 were included in the comparison group. Sensitivity analysis was performed via Monte Carlo simulation and tornado diagram.Results: The results indicated that the POC-A1c device used in the primary care unit was a cost-effective alternative, which improved access to A1c tests and resulted in an increased rate of early control of blood glucose. In the 10-year period, POC-A1c group presented a mean cost of US$10,503.48 per patient and an effectiveness of 0.35 vs. US$9,992.35 and 0.09 for the traditional laboratory test, respectively. The incremental cost was US$511.13 and the incremental effectiveness was 0.26, resulting in an incremental cost-effectiveness ratio of 1,947.10. In Monte Carlo simulation, costs and effectiveness ranged between $9,663.20–$10,683.53 and 0.33–0.37 for POC-A1c test group, and $9,288.28–$10,413.99 and 0.08–0.10 for traditional laboratory test group, at 2.5 and 97.5 percentiles. The costs for nephropathy, retinopathy, and cardiovascular disease and the probability of being hospitalized due to diabetes presented the greatest impact on the model’s result.Conclusion: This study showed that using POC-A1c devices in primary care settings is a cost-effective alternative for monitoring glycated hemoglobin A1c as a marker of blood glucose control in people living with type 2 diabetes. According to our model, the use of POC-A1c device in a healthcare unit increased the early control of type 2 diabetes and, consequently, reduced the costs of diabetes-related outcomes, in comparison with a centralized laboratory test.

Funder

Medtronic Foundation

Publisher

Frontiers Media SA

Subject

Pharmacology (medical),Pharmacology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3