In vitro assessment of periapical lesions created in sheep mandibles by using high resolution ultrasonography and cone beam computed tomography

Author:

Kamburoğlu Kıvanç1,Çakmak Esra Ece1,Eratam Nejlan1,Sönmez Gül2,Karahan Sevilay3

Affiliation:

1. Dept of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey

2. Dept of Dentomaxillofacial Radiology, Faculty of Dentistry, Adakent University, via Mersin 10, Turkey

3. Dept of Biostatistics, Faculty of Medicine, Hacettepe University, Ankara, Turkey

Abstract

Objectives: Providing ultrasound images of periapical lesions may be problematic depending on the thickness of the overlying cortical bone. Clinically, it is crucial to determine the cut-off value of overlaying bone thickness in terms of interference with ultrasound imaging in conjunction with assessment of changes in periapical jaw bone lesions. Our aim was to determine the minimum amount of overlaying buccal bone thickness of artificial periapical lesions in order to be visible by ultrasound imaging and to compare width, height, depth, surface area and volume measurements of detectable periapical lesions obtained from ultrasound and CBCT images. Methods: Periapical lesions were created in 16 molar teeth of sheep mandibles. Cavities were enlarged until the borders of lesions were visible on 14 MHz hockey probe ultrasound imaging. CBCT and ultrasound images were obtained simultaneously after drilling and enlarging each size of the cavities and replacing the teeth in their sockets. two observers separately assessed images twice within 2 weeks of interval. By using CBCT and ultrasound images, buccal bone thickness, maximum width, height, depth, surface area and volume of periapical lesions were measured. Intraclass correlation coefficient (ICC) was utilized and significance level was set at p < 0.05. Results: The mean buccal bone thickness ranged between 1.21 mm and 1.31 mm for both imaging techniques. For the measurement of buccal bone thickness, periapical lesion width, height, depth, surface area, and volume excellent ICC values were found in terms of intrarater (ranging between 0.907 and 1) and inter-rater (ranging between 0.864 and 1) reliability for both observers and their readings. There were no statistically significant differences for both observers and for their two readings between ultrasound and CBCT measurements of buccal bone thickness, and periapical lesion width and height (p > 0.05). Conclusions: We suggested that a buccal thickness of approximately 1.28 mm might be accepted as a cut-off value for the detection of periapical lesions with 14 MHz hockey probe ultrasound. High resolution ultrasound provided accurate information for the measurement of buccal bone thickness and lesion width and height.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3