Effect of field of view (FOV) positioning and shielding on radiation dose in paediatric CBCT

Author:

Vogiatzi Theodosia1,Menz Roman2,Verna Carlalberta3,Bornstein Michael M.1,Dagassan-Berndt Dorothea4

Affiliation:

1. Department of Oral Health and Medicine, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland

2. Division of Radiological Physics, Department of Radiology, University of Basel, Basel, Switzerland

3. Department of Paediatric Oral Health and Orthodontics, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland

4. Center for Dental Imaging, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland

Abstract

Objective: To investigate the effect of two different large field of view (FOV) positions in the vertical dimension and shielding (thyroid collar and eyeglasses) on the effective dose and the local doses of various sites of the craniofacial complex. Methods: Organ doses and effective doses were calculated based on the measured doses using 27 pairs of thermoluminescent dosemeters in a paediatric tissue-equivalent of a 10-year-old anthropomorphic phantom. The large FOV of the 3D Accuitomo F170 CBCT scanner was used to image parts of the craniofacial complex. Six protocols were performed: (A) cranial position without shielding; (B) cranial position with shielding; (C) caudal position without shielding; (D) caudal position with shielding, (E) similar to C with 3600 rotation and (F) similar to D with 360° rotation. Measurements were obtained in duplicate, and the relative δ value (%) was applied to compare the average doses between the protocols. Results: Changing the FOV position from cranial to caudal without using shielding resulted in an increase of the effective dose of 18.8%. Use of shielding in the caudal position reduced the dose by 31.6%. Local absorbed dose of the thyroid had the most relevant impact on calculation of the effective dose, followed by oesophagus, bone marrow and bone surfaces, especially when comparing the different protocols. Conclusions: Application of shielding devices for thyroid in combination with a most caudal positioning of FOV led to the lowest local absorbed doses as well as the effective dose in a child phantom model.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3