Comparative study of conventional diffusion-weighted imaging and introvoxel incoherent motion in assessment of pathological grade of clear cell renal cell carcinoma

Author:

Zhu Qingqiang1,Zhu Wenrong1,Wu Jingtao1,Chen Wenxin1,Ye Jing1,Ling Jun1

Affiliation:

1. Department of Medical Imaging, Clinical Medical College, Yangzhou University, Yangzhou, China

Abstract

Objective: To quantitatively compare the diagnostic values of conventional diffusion-weighted imaging (DWI) and introvoxel incoherent motion (IVIM) analysis of microstructural differences for clear cell renal cell carcinoma (ccRCC). Methods: Multiple b value DWIs and IVIMs were performed in patients with 146 ccRCCs, 42 with Grade Ⅰ, 46 with Grade Ⅱ, 28 with Grade Ⅲ and 30 with Grade Ⅳ. These tumours were divided into low (Ⅰ+Ⅱ, n = 88) and high grades (Ⅲ+Ⅳ, n = 58). The diagnostic efficacy of various diffusion parameters for predicting ccRCC grades was compared. Results: The mean signal-to-noise ratios (SNRs) of IVIM images at b = 0, 800 and 1500 s/mm2 were 31.9, 12.3 and 8.4, respectively. The apparent diffusion coefficient (ADC), D and D* values correlated negatively with ccRCC grading (r = -0.786,–0.913, −0879, p < 0.05). f values correlated positively with ccRCC grading (r = 0.811, p < 0.05). The ADC, D and D* values were higher for Grade Ⅱ ccRCC than that of Grade Ⅲ ccRCC (p < 005), however, f values were higher for Grade Ⅲ ccRCC than that of Grade Ⅱ ccRCC (p < 005). Receiver operating characteristic curve analyses showed that D values had the highest diagnostic efficacy in differentiating low/high and Ⅱ/Ⅲ ccRCC grading. The area under the curve, sensitivity, specificity and accuracy of the D values were 0.963, 0.960; 90.9%, 89.1%; 81.0%,78.6 and 89.0%, 87.8%, respectively. For pairwise comparisons of receiver operating characteristic curves and diagnostic efficacy, ADC was worse than IVIM (all p < 0.05). Conclusion: IVIM parameters have better performance than ADC in differentiating ccRCC grading, given an adequate SNR of IVIM images. Advances in knowledge: 1. D values had the highest diagnostic efficacy in differentiating low/high and Ⅱ/Ⅲ ccRCC grading. 2. IVIM parameters have better performance than ADC in differentiating ccRCC grading, given an adequate SNR of IVIM images. 3. The ADC, D and D* values correlated negatively with ccRCC grading, however, f values correlated positively with ccRCC grading.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3