The dosimetric underpinning of bladder filling criteria for prostate image-guided volumetric modulated arc therapy

Author:

Kong Vickie12ORCID,Dang Jennifer1,Wan Vanessa1,Rosewall Tara12

Affiliation:

1. Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada

2. Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada

Abstract

Objectives: Repeated CT simulation imaging is common at our institution due to failure to achieve acceptable bladder filling in patients undergoing prostate radiotherapy. There is operational value in re-assessing the validity of the bladder filling assessment criteria by comparing the quality of two plans optimized based on either an “Accepted” or “Rejected” bladder status. Methods: Twenty prostate patients with repeated CT simulation imaging were included. For each patient, a VMAT plan created using the “Rejected” bladder was compared with the “Accepted” bladder plan. Then, delivered dose to bladder was estimated using ≥4 CBCTs to measure number of fractions with major bladderdose violation (>5% difference) for both plans. Bladder heights of fractions without major bladder dose violations were compared to those with a violation to determine a threshold height for bladder filling acceptability. Results: Using the “Accepted” bladder plans for treatment resulted in 30/175 fractions with major dose violations. These 30 bladders were significantly shorter than those without major violation (mean 28 vs 43mm, p < 0.05). The “Rejected” bladder plans delivered a lower dose to the bladder by ≥5% than the ‘“Accepted” bladder plans in 59% of fractions, and the number of fractions with major dose violations was 17. Conclusions: Using a shorter bladder for plan optimization resulted in better bladder sparing during treatment and improved compliance to protocol specific bladder dose constraints. A bladder height range of 20–40 mm measured between the bladder dome and the superior aspect of the symphysis pubis is recommended for prostate radiotherapy requiring a full bladder protocol. Advances in knowledge: Using real patient data from simulation and treatment, this study established a range of bladder height that can be measured easily in a clinical setting for assessing adequacy of bladder filling for prostate radiotherapy.

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3