Validation of a 3D CBCT-based protocol for the follow-up of mandibular condyle remodeling

Author:

Verhelst Pieter-Jan12ORCID,Shaheen Eman12,de Faria Vasconcelos Karla1,Van der Cruyssen Fréderic12,Shujaat Sohaib1,Coudyzer Walter3,Salmon Benjamin45,Swennen Gwen6,Politis Constantinus12,Jacobs Reinhilde127

Affiliation:

1. OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium

2. Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium

3. Department of Radiology, University Hospitals Leuven, Leuven, Belgium

4. Orofacial Pathologies, Imaging and Biotherapies EA2496 Lab, University of Paris, Montrouge, France

5. Dental Medicine Department, AP-HP, Bretonneau Hospital, Paris, France

6. Division of Maxillofacial Surgery, Department of Surgery, AZ Sint-Jan Brugge-Oostende AV, Bruges, Belgium

7. Department of Dental Medicine, Karolinska Institutet, Stockholm, Sweden

Abstract

Objectives: Three-dimensional models of mandibular condyles provide a way for condylar remodeling follow-up. The overall aim was to develop and validate a user-friendly workflow for cone beam CT (CBCT)-based semi-automatic condylar registration and segmentation. Methods: A rigid voxel-based registration (VBR) technique for registration of two post-operative CBCT-scans was tested. Two modified mandibular rami, with or without gonial angle, were investigated as the volume of interest for registration. Inter- and intraoperator reproducibility of this technique was tested on 10 mandibular rami of orthognathic patients by means of intraclass correlation coefficients (ICC’s) and descriptive statistics of the transformation values from the VBR. The difference in reproducibility between the two modified rami was evaluated using a paired t-test (p < 0.05). For the segmentation, eight fresh frozen cadaver heads were scanned with CBCT and micro-CT. These data were used to test the inter- and intraoperator reproducibility (ICC’s) and accuracy (Bland–Altman plot) of a newly designed workflow based on semi-automated contour enhancement. Results: Excellent ICC’s (0.94–0.99) were obtained for the voxel-based registration technique using both modified rami. If the gonial angle was not included in the volume of interest, there was a trend of increased operator error suggested by significant higher interoperator differences in translation values (p = 0,0036). The segmentation workflow proved to be highly reproducible with excellent ICC’s (0.99), low absolute mean volume differences between operators (23.19 mm3), within operators (28.93 mm3) and low surface distances between models of different operators (<0.20 mm). Regarding the accuracy, CBCT-models slightly overestimate the condylar volume compared to micro-CT. Conclusions: This study provides a validated user-friendly and reproducible method of creating three-dimensional-surface models of mandibular condyles out of longitudinal CBCT-scans.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370