Abstract

In this study, electric field and magnetic flux density pollution levels were measured in southern Africa, a case of Blantyre City in Malawi, between 2020 and 2021. Sixty short-term measurements were performed using Trifield Electro Magnetic Frequency meter model TF2 in 30 different locations. Five high-population-dense sampling points were selected from school campuses, hospitals, industrial areas, markets, residential areas, and within the commercial and business center (CBC) of Blantyre. Electric field and magnetic flux density pollution monitoring was conducted between 10:00–12:00 h and 17:00–19:00 h for short-range analysis. Short-range results show that the maximum measured electric field pollution were 249.24 mV/m and 207.85 mV/m between 10:00–12:00 and 17:00–19:00 respectively, which are below the public limits of 4200.00 mV/m for public exposure. Similarly, maximum short-range results for magnetic flux density were 0.073 G and 0.057 G between 10:00–12:00 and 17:00–19:00 respectively which are below the public limits of 2 G for public exposure. Both measured electric and magnetic flux density were compared with the International Commission on Non-Ionizing Radiation Protection (ICNIRP), World health organization (WHO), and Institute of electrical and electronics engineers (IEEE). It was determined that all measured values for both electric and magnetic flux density were smaller than set limits for non-ionizing radiation for both public and occupation health. More importantly, these background measurements establish a baseline for future changes to be compared against public safety.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3