Novel Investigation of Higher Order Spectral Technologies for Fault Diagnosis of Motor-Based Rotating Machinery

Author:

Ciszewski Tomasz1ORCID,Gelman Len2,Ball Andrew2ORCID,Abdullahi Abdulmumeen Onimisi2,Jamabo Biebele2,Ziolko Michal3

Affiliation:

1. Faculty of Electrical Engineering, Gdynia Maritime University, 81-255 Gdynia, Poland

2. School of Computing and Engineering, University of Huddersfield, Huddersfield HD1 3DH, UK

3. Faculty of Electrical and Control Engineering, Gdańsk University of Technology, 80-233 Gdansk, Poland

Abstract

In the last decade, research centered around the fault diagnosis of rotating machinery using non-contact techniques has been significantly on the rise. For the first time worldwide, innovative techniques for the diagnosis of rotating machinery, based on electrical motors, including generic, nonlinear, higher-order cross-correlations of spectral moduli of the third and fourth order (CCSM3 and CCSM4, respectively), have been comprehensively validated by modeling and experiments. The existing higher-order cross-correlations of complex spectra are not sufficiently effective for the fault diagnosis of rotating machinery. The novel technology CCSM3 was comprehensively experimentally validated for induction motor bearing diagnosis via motor current signals. Experimental results, provided by the validated technology, confirmed high overall probabilities of correct diagnosis for bearings at early stages of damage development. The novel diagnosis technologies were compared with existing diagnosis technologies, based on triple and fourth cross-correlations of the complex spectra. The comprehensive validation and comparison of the novel cross-correlation technologies confirmed an important non-traditional novel outcome: the technologies based on cross-correlations of spectral moduli were more effective for damage diagnosis than the technologies based on cross-correlations of the complex spectra. Experimental and simulation validations confirmed a high probability of correct diagnosis via the CCSM at the early stage of fault development. The average total probability of incorrect diagnosis for the CCSM3 for all experimental results of 8 tested bearings, estimated via 6528 diagnostic features, was 1.475%. The effectiveness gains in the total probability of incorrect diagnosis for the CCSM3 in comparison with the CCCS3 were 26.8 for the experimental validation and 18.9 for the simulation validation. The effectiveness gains in the Fisher criterion for the CCSM3 in comparison with the CCCS3 were 50.7 for the simulation validation and 104.7 for the experimental validation.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3