Abstract
This study aimed to reveal the influence of the draw ratio and take-up speed on the pore size distribution and morphology of the hollow fiber ultrafiltration membrane selective layer. To this end, spinnerets with ring ducts of 1.8 and 1.3 mm were employed, whereas the external diameter of the obtained fiber was kept equal. Atomic force microscopy and scanning electron microscopy were employed to study the morphology of the selective layer. Liquid–liquid displacement porosimetry was used to determine the limiting pore size distribution. The produced polyethersulfone ultrafiltration membranes had a robust, sponge-like porous structure, permeance 1000 L/(m2·h·bar), smooth selective layer, and mean pore size 25 nm. It was found that limiting pore sizes are affected more by the change in the take-up speed, whereas the surface pore sizes, roughness, and morphology are controlled by the draw ratio. It was shown that excessive draw causes the selective layer stretching and crop-up of the porous sublayer. Consequently, the diameters of the spinneret ring duct and the bore needle should match the hollow fiber outer and lumen diameters, respectively.
Subject
Mechanics of Materials,Biomaterials,Civil and Structural Engineering,Ceramics and Composites
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献