Position of the ISTENT Inject® Trabecular Micro-Bypass System Visualized with the NIDEK GS-1 Gonioscope—A Postoperative Analysis

Author:

Zimmermann Julian Alexander1,Storp Jens Julian1ORCID,Merté Ralph-Laurent1,Heiduschka Peter1,Eter Nicole1,Brücher Viktoria Constanze1ORCID

Affiliation:

1. Department of Ophthalmology, University of Muenster Medical Center, 48149 Muenster, Germany

Abstract

Glaucoma is one of the leading causes of irreversible blindness globally and is characterized by the gradual loss of retinal ganglion cells. The primary risk factor for the development and progression of glaucoma is increased intraocular pressure (IOP). Numerous surgical interventions exist to lower IOP should conservative therapy fail. One trend in recent years has been minimally invasive glaucoma surgery (MIGS) as an alternative to traditional methods. The ISTENT inject® is an ab interno trabecular micro-bypass implant designed to be implanted through the trabecular meshwork into the Schlemm’s canal to lower IOP. The aim of the study was the postoperative visualization and description of the positioning of the ISTENT inject® using automated circumferential goniophotography. Patients with symptomatic cataracts and mild to moderate primary open-angle glaucoma (POAG), pseudoexfoliation glaucoma (PEX), and pigment-dispersion glaucoma were included who underwent combined cataract surgery with the ISTENT inject® and received postoperative automated gonioscopy with the NIDEK Gonioscope GS-1 to visualize the location of the implant. Twenty-four implants of 14 eyes in 11 patients could be visualized. Out of the implants, 14.3% were in the trabecular meshwork, 46.4% were at the border between the trabecular meshwork and scleral spur, 25% were below the trabecular meshwork, and 14.3% of the implants were not detectable in the gonioscopy. In the overall cohort, a statistically significant IOP reduction was found over the 12-month postoperative observation period. Even in three eyes, in each of which both stents were located below the trabecular meshwork, an IOP reduction over 12 months was observed compared to the baseline IOP. In this study, vertical two-dimensional positioning of the ISTENT inject® was performed for the first time using NIDKE GS-1 automated 360° goniophotography. The method is suitable for postoperative visualization, control, and documentation of positioning after ISTENT inject® implantation. Further studies are needed to analyze the correlation between positioning of the ISTENT inject® in the chamber angle and postoperative IOP reduction.

Funder

Open Access Publication Fund of the University of Muenster

Publisher

MDPI AG

Subject

General Medicine

Reference30 articles.

1. The Pathophysiology and Treatment of Glaucoma: A Review;Weinreb;JAMA,2014

2. Glaucoma;Jonas;Lancet,2017

3. Laser in Glaucoma and Ocular Hypertension (LiGHT) Trial: Six-Year Results of Primary Selective Laser Trabeculoplasty versus Eye Drops for the Treatment of Glaucoma and Ocular Hypertension;Gazzard;Ophthalmology,2023

4. Aktuelle Glaukomchirurgie;Hoffmann;Ophthalmologe,2021

5. U.S. Food & Drug Administration (2023, July 01). Premarket Approval (PMA), Available online: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P170043.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3