Development and Validation of a Reliable UHPLC-MS/MS Method for Simultaneous Quantification of Macrocyclic Lactones in Bovine Plasma

Author:

Zeleke GemechuORCID,De Baere SiegridORCID,Suleman Sultan,Devreese MathiasORCID

Abstract

A fast, accurate and reliable ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) method was developed for simultaneous quantification of ivermectin (IVER), doramectin (DORA), and moxidectin (MOXI) in bovine plasma. A priority for sample preparation was the eradication of possible infectious diseases to avoid travel restrictions. The sample preparation was based on protein precipitation using 1% formic acid in acetonitrile, followed by Ostro® 96-well plate pass-through sample clean-up. The simple and straightforward procedure, along with the short analysis time, makes the current method unique and suitable for a large set of sample analyses per day for PK studies. Chromatographic separation was performed using an Acquity UPLC HSS-T3 column, with 0.01% acetic acid in water and methanol, on an Acquity H-Class ultra-high performance liquid chromatograph (UHPLC) system. The MS/MS instrument was a Xevo TQ-S® mass spectrometer, operating in the positive electrospray ionization mode and two multiple reaction monitoring (MRM) transitions were monitored per component. The MRM transitions of m/z 897.50 > 753.4 for IVER, m/z 921.70 > 777.40 for DORA and m/z 640.40 > 123.10 for MOXI were used for quantification. The method validation was performed using matrix-matched calibration curves in a concentration range of 1 to 500 ng/mL. Calibration curves fitted a quadratic regression model with 1/x2 weighting (r ≥ 0.998 and GoF ≤ 4.85%). Limits of quantification (LOQ) values of 1 ng/mL were obtained for all the analytes, while the limits of detection (LOD) were 0.02 ng/mL for IVER, 0.03 ng/mL for DORA, and 0.58 ng/mL for MOXI. The results of within-day (RSD < 6.50%) and between-day (RSD < 8.10%) precision and accuracies fell within acceptance ranges. No carry-over and no peak were detected in the UHPLC-MS/MS chromatogram of blank samples showing good specificity of the method. The applicability of the developed method was proved by an analysis of the field PK samples.

Funder

Jimma University

Publisher

MDPI AG

Subject

Chemistry (miscellaneous),Analytical Chemistry,Organic Chemistry,Physical and Theoretical Chemistry,Molecular Medicine,Drug Discovery,Pharmaceutical Science

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3