Abstract

Sulfur hexafluoride (SF6), which survives in the atmosphere for an extremely long period of time, is the most potent greenhouse gas regulated under the Kyoto Protocol. So, the accurate monitoring of atmospheric SF6 plays an important role in the study of the control policies for reducing greenhouse gas emissions. The instruments for SF6 measurement are typically calibrated using certified reference materials. The concentrations of the commercially available SF6 reference materials usually have a broad range, from 1 μmol/mol to 6000 μmol/mol. Some characteristics including sensitivity, linear range, relative standard deviation, and accuracy are crucial for the determination of SF6 in such a broad concentration range. Therefore, the selection of a proper detector for the accurate determination of SF6 with such a broad range is extremely important to establish a gas chromatography (GC) method for developing SF6 reference materials. In this paper, several typical GC methods with different detectors, including a thermal conductivity detector (TCD), a pulsed discharge helium ionization detector (PDHID), and a flame photometric detector (FPD), were carefully established for the accurate determination of SF6 with different concentrations. The results show that an FPD detector has a relatively narrow linearity range, thus a quadratic equation should be established for building a calibration curve. The PDHID and TCD have good linearity with coefficients of 1.0000 in the concentration range of 10–100 μmol/mol (using a PDHID), and 100–1000 μmol/mol (using a TCD), respectively. Further considering the measurement errors of indication results, the PDHID is suitable for SF6 measurement when the concentrations are below 100 μmol/mol, whereas the TCD is suitable for SF6 measurement when the concentrations are over 100 μmol/mol. These results provide useful guidance in choosing an appropriate GC detector for the accurate determination of SF6, which are especially very helpful for developing SF6 reference materials.

Publisher

MDPI AG

Reference25 articles.

1. History of atmospheric SF6 from 1973 to 2008;Rigby;Atmos. Chem. Phys.,2010

2. Atmospheric SF6: Trends, sources and prospects;Maiss;Environ. Sci. Technol.,1998

3. Tropospheric SF6: Age of air from the Northern Hemisphere midlatitude surface;Waugh;J. Geophys. Res. Atmos.,2013

4. EPA: Overview of SF6 Emissions Sources and Reduction Options in Electric Power Systems, U.S (2019, December 05). Environmental Protection Agency, Available online: https://www/epa.gov/f-gas-partnership-programs/overview-SF6-emissions-sources-and-reduction-options-elctric-power.

5. The increasing atmospheric burden of the greenhouse gas sulfur hexafluoride (SF6);Peter;Atmos. Chem. Phys.,2020

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3