Affiliation:
1. Department of Civil Engineering, College of Engineering, The American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates
2. Qeyas Contracting L.L.C., Dubai P.O. Box 74956, United Arab Emirates
Abstract
Nowadays, fiber-reinforced polymer (FRP) has become a widely accepted alternative reinforcement to steel bars in concrete members due to its many sustainability traits, as represented by its high strength-to-weight ratio, corrosion resistance, non-conductive properties, and electromagnet neutrality. However, FRP bar exposure for an extended period of time to harsh environmental conditions and chemicals can have an adverse effect on their mechanical properties. In this investigation, glass FRP bars were exposed to indoor controlled temperature, outdoor direct sunlight, outdoor shade, seawater, and alkaline solution for six months prior to using them as reinforcement in concrete flexural members. This research involves the fabrication and testing of five pairs of 3 m-long concrete beams with 200 mm by 300 mm cross-sections embedded in the tension zone with the exposed GFRP bars. The 10 beams were instrumented with strain gauges and tested following a four-point loading scheme using a hydraulic jack attached to a rigid steel frame. Crack width records from the tests showed the inferior serviceability of the beams that contained rebars stored in an outdoor environment relative to the control beams. GFRP bar exposure to an alkaline solution or outdoor direct sunlight slightly affected the cracking and ultimate moment capacities, reducing them by 5% and 3% in terms of the same parameters as the controlled indoor exposure, respectively. The influence of GFRP bar exposure to open-air shade or sunlight decreased the pre-cracking stiffness by 25% and flexural ductility by 10–20% when compared with the control specimens. The predicted ultimate flexural strength using the ACI 440 provisions gave comparable results to the experimentally obtained values. A simple mathematical equation that envelops the moment–deflection relationship for GFRP over-reinforced concrete beams and only requires information about initial cracking and ultimate flexural conditions is proposed.
Funder
American University of Sharjah
College of Engineering
Reference30 articles.
1. Li, S., Lv, H., Huang, T., Zhang, Z., Yao, J., and Ni, X. (2022). Degradation of Reinforced Concrete Beams Subjected to Sustained Loading and Multi-Environmental Factors. Buildings, 12.
2. Environmental and mechanical performance of different fiber reinforced polymers in beams;Sbahieh;Mater. Today Proc.,2022
3. A review on FRP bars and supplementary cementitious materials for the next generation of sustainable and durable construction materials;Ji;Constr. Build. Mater.,2023
4. A Critical Review on Glass Fiber-Reinforced Polymer Bars as Reinforcement in Flexural Members;Kinjawadekar;J. Inst. Eng. (India) Ser. A,2023
5. Short-term durability test for GFRP rods under various environmental conditions;Kim;Compos. Struct.,2008