Comparison of the Efficiency of Selected Disinfectants against Planktonic and Biofilm Populations of Escherichia coli and Staphylococcus aureus

Author:

Todorić Olja1ORCID,Pezo Lato2ORCID,Šarić Ljubiša1ORCID,Kolarov Violeta3,Varga Ana1,Čabarkapa Ivana1ORCID,Kocić-Tanackov Sunčica4

Affiliation:

1. Institute of Food Technology, University of Novi Sad, Bulevar cara Lazara 1, 21000 Novi Sad, Serbia

2. Institute of General and Physical Chemistry, University of Belgrade, Studentski trg 12/V, 11000 Belgrade, Serbia

3. Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 3, 21000 Novi Sad, Serbia

4. Faculty of Technology, University of Novi Sad, Bulevar cara Lazara 1, 21000 Novi Sad, Serbia

Abstract

The aim of this study is to compare the efficacy of selected food disinfectants on planktonic populations of Staphylococcus aureus and Escherichia coli and on the same microorganisms (MOs) incorporated in a biofilm. Two disinfectants were used for treatment: peracetic acid-based disinfectant (P) and benzalkonium chloride-based disinfectant (D). Testing of their efficacy on the selected MO populations was performed using a quantitative suspension test. The standard colony counting procedure was used to determine their efficacy on bacterial suspensions in tryptone soy agar (TSA). The germicidal effect (GE) of the disinfectants was determined based on the decimal reduction ratio. For both MOs, 100% GE was achieved at the lowest concentration (0.1%) and after the shortest exposure time (5 min). Biofilm production was confirmed with a crystal violet test on microtitre plates. Both E. coli and S. aureus showed strong biofilm production at 25 °C with E. coli showing significantly higher adherence capacity. Both disinfectants show a significantly weaker GE on 48 h biofilms compared to the GE observed after application of the same concentrations on planktonic cells of the same MOs. Complete destruction of the viable cells of the biofilms was observed after 5 min of exposure to the highest concentration tested (2%) for both disinfectants and MOs tested. The anti-quorum sensing activity (anti-QS) of disinfectants P and D was determined via a qualitative disc diffusion method applied to the biosensor bacterial strain Chromobacterium violaceum CV026. The results obtained indicate that the disinfectants studied have no anti-QS effect. The inhibition zones around the disc therefore only represent their antimicrobial effect.

Funder

Ministry of Science, Technological Development and Innovation of the Republic of Serbia under the Agreements on the Implementation and Financing of Research

Provincial Secretariat for Higher Education and Scientific Research, Autonomous Province of Vojvodina, Republic of Serbia

Publisher

MDPI AG

Subject

Virology,Microbiology (medical),Microbiology

Reference57 articles.

1. Biofilm. Microbial pathogens and strategies for combating them;Cabarkapa;Sci. Tech. Ed.,2013

2. Biofilm formation by Salmonella spp. and Listeria monocytogenes on plastic surface;Ranin;Lett. Appl. Microbiol.,2004

3. Control of Salmonella in food related environments by chemical disinfection;Heir;Food Res. Int.,2012

4. Crystal violet binding assay for assessment of biofilm formation by Listeria monocytogenes and Listeria spp. on wood, steel and glass surfaces;Adetunji;Glob. Vet.,2011

5. Attachment of different Salmonella serovars to materials commonly used in a poultry processing plant;Chia;Food Microbiol.,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3