Feasibility Analysis of Indirect Evaporative Cooling System Assisted by Liquid Desiccant for Data Centers in Hot-Humid Regions

Author:

Shi Wenchao1ORCID,Ma Xiaochen1,Min Yunran2,Yang Hongxing1

Affiliation:

1. Renewable Energy Research Group (RERG), Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China

2. College of Marine Equipment and Mechanical Engineering, Jimei University, Xiamen 361021, China

Abstract

The rapid development of data centers (DCs) has led to a marked increase in energy consumption in recent years, which poses a direct challenge to global efforts aimed at reducing carbon emissions. In regions with hot and humid climates, the energy demand is largely driven by air conditioning systems necessarily to maintain appropriate operational temperatures. This study proposes a novel multi-stage indirect evaporative cooling (IEC) system, incorporating a liquid desiccant in the primary air channel to address the cooling demands of such DCs. Our approach involves a two-stage process where the first stage uses a liquid desiccant-based IEC (LD-IEC) for air dehumidification and the second stage utilizes the treated air from the first stage as the secondary air to enhance the cooling effect. A simulation model of the proposed system is established with validation, and the performance of the multi-stage system was also discussed based on different operation modes. Furthermore, a case study was conducted to investigate the feasibility of using this system in the DC under a typical hot and humid zone. The findings reveal that the first-stage LD-IEC is capable of diminishing the wet-bulb temperature of the ambient air. Furthermore, the case study demonstrates that the proposed system can greatly improve the temperature drop by 72.7% compared to the single IEC, which noticeably reduces the operation time of energy-intensive supplementary cooling equipment from 5092 h to 31 h given the supply air temperature threshold of 25 °C. In summary, the proposed system could substantially decrease reliance on traditional cooling systems, which demonstrates a promising avenue to fully use this passive cooling technology for cooling DCs.

Funder

National Natural Science Foundation of China

PolyU Distinguished Postdoctoral Fellowship Scheme

Publisher

MDPI AG

Reference44 articles.

1. A net-zero emissions strategy for China’s power sector using carbon-capture utilization and storage;Fan;Nat. Commun.,2023

2. A vision of dew point evaporative cooling: Opportunities and challenges;Lai;Appl. Therm. Eng.,2024

3. Photovoltaics and Energy Storage Integrated Flexible Direct Current Distribution Systems of Buildings: Definition, Technology Review, and Application;Liu;CSEE J. Power Energy Syst.,2023

4. Evaluation of passive envelope systems with radiative sky cooling and thermally insulated glazing materials for cooling;Chen;J. Clean. Prod.,2023

5. Real life test of a novel super performance dew point cooling system in operational live data centre;Ma;Appl. Energy,2023

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3