Clogging Behaviors in PVD and Their Evaluation Criteria for Dredged Mud Slurry

Author:

Bao Shufeng12ORCID,Guo Lingfeng3ORCID,Dong Zhiliang45,Zhou Ruibo6,Zhou Shuangxi12,Chen Jian7

Affiliation:

1. School of Civil & Engineering Management, Guangzhou Maritime University, Guangzhou 510725, China

2. Guangdong Provincial Key Laboratory of Green Construction and Intelligent Operation & Maintenance for Offshore Infrastructure, Guangzhou 510725, China

3. School of Civil Engineering & Transportation, South China University of Technology, Guangzhou 510641, China

4. CCCC Fourth Harbor Engineering Institute Co., Ltd., Guangzhou 510230, China

5. CCCC Key Lab of Environmental Protection & Safety in Foundation Engineering of Transportation, Guangzhou 510230, China

6. CCCC FHEC Harbor Engineering Design Co., Ltd., Guangzhou 510220, China

7. Guangzhou Institute of Railway Technology, Guangzhou 510430, China

Abstract

During the consolidation period of vacuum preloading drainage of dredged mud slurry, the clogging behaviors of the filter drainage structural layers and the core boards of prefabricated vertical drains (PVD) determine the drainage capacities of PVD. However, currently, there is a lack of comprehensive research on the evaluation criteria for these two clogging behaviors. Therefore, based on typical dredged mud slurry, typical geomembranes, and raw material core boards with different bending forms, relevant macro and micro-scale experimental studies have been carried out in this study. The research results show that (1) with the application of the gradient ratio test method, the clogging behaviors of filter membranes of PVD under graded vacuum preloading can be effectively simulated. Also, in the design of graded vacuum preloading, characteristics of equivalent pore sizes and pore structures should be emphasized to investigate the suitability of filtration and drainage performance of PVD filter membranes. (2) The compressive yield strength of core board grooves is a key factor influencing the reduction rate of flow capacity. The reduction rate of flow capacity and well resistance increment can be used as comprehensive indicators reflecting the clogging behaviors of core boards, while the bending angles and bending rates of core boards can be used as specific technical indicators. (3) The proposed clogging evaluation criteria for PVD are as follows: a filter membrane gradient ratio (GR) > 4.0, a core board bending rate >60% and a core board bending angle < 45°, or a reduction rate of flow capacity of bending drainage board > 90% or well-resistance increment > 9. Also, these criteria can be incorporated into the control indicators for drainage performance of PVD used in such types of foundations.

Funder

National Natural Science Foundation of China

Guangdong University Innovation Team Project

Guangdong Basic and Applied Basic Research Foundation

Publisher

MDPI AG

Subject

Water Science and Technology,Aquatic Science,Geography, Planning and Development,Biochemistry

Reference31 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3