Analysis of Individual V˙O2max Responses during a Cardiopulmonary Exercise Test and the Verification Phase in Physically Active Women

Author:

Succi Pasquale J.1ORCID,Benitez Brian1,Kwak Minyoung1,Bergstrom Haley C.1

Affiliation:

1. Department of Kinesiology and Health Promotion, University of Kentucky, Lexington, KY 40536, USA

Abstract

This study aimed to investigate the test–retest reliability, mean, and individual responses in the measurement of maximal oxygen consumption (V˙O2max) during a cardiopulmonary exercise test (CPET) and the verification phase during cycle ergometry in women. Nine women (22 ± 2 yrs, 166.0 ± 4.5 cm, 58.6 ± 7.7 kg) completed a CPET, passively rested for 5 min, and then completed a verification phase at 90% of peak power output to determine the highest V˙O2 from the CPET (V˙O2CPET) and verification phase (V˙O2verification) on 2 separate days. Analyses included a two-way repeated measures ANOVA, intraclass correlation coefficients (ICC2,1), standard errors of the measurement (SEM), minimal differences (MD), and coefficients of variation (CoV). There was no test (test 1 versus test 2) × method (CPET vs. verification phase) interaction (p = 0.896) and no main effect for method (p = 0.459). However, test 1 (39.2 mL·kg−1·min−1) was significantly higher than test 2 (38.3 mL·kg−1·min−1) (p = 0.043). The V˙O2CPET (ICC = 0.984; CoV = 1.98%; SEM = 0.77 mL·kg−1·min−1; MD = 2.14 mL·kg−1·min−1) and V˙O2verification (ICC = 0.964; CoV = 3.30%; SEM = 1.27 mL·kg−1·min−1; MD = 3.52 mL·kg−1·min−1) demonstrated “excellent” reliability. Two subjects demonstrated a test 1 V˙O2CPET that exceeded the test 2 V˙O2CPET, and one subject demonstrated a test 1 V˙O2verification that exceeded the test 2 V˙O2verification by more than the respective CPET and verification phase MD. One subject demonstrated a V˙O2CPET that exceeded the V˙O2verification, and one subject demonstrated a V˙O2verification that exceeded the V˙O2CPET by more than the MD. These results demonstrate the importance of examining the individual responses in the measurement of the V˙O2max and suggest that the MD may be a useful threshold to quantify real individual changes in V˙O2.

Publisher

MDPI AG

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Histology,Rheumatology,Anatomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3