Abstract
To ensure optimum working conditions for lithium-ion batteries, a numerical study is carried out for three-dimensional temperature distribution of a battery liquid cooling system in this work. The effect of channel size and inlet boundary conditions are evaluated on the temperature field of the battery modules. Based on the thermal behavior of discharging battery obtained experimental measurements, two temperature control strategies are proposed and studied. The results show that the channel width of the cooling plates has a great influence on the maximum temperature in the battery module. It is also revealed that increasing inlet water flow rate can significantly improve the heat transfer capacity of the battery thermal management system, while the relationship between them is not proportional. Lowering the inlet temperature can reduce the maximum temperature predicted in the battery module significantly. However, this will also lead to additional energy consumed by the cooling system. It is also found that the Scheme 5 among various temperature control strategies can ensure the battery pack working in the best temperature range in different depths of discharge. Compared with the traditional one with a given flow rate, the parasitic energy consumption in Scheme 5 can be reduced by around 80%.
Funder
National Natural Science Foundation of China
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
66 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献