Calibration and Cross-Validation of Accelerometer Cut-Points to Classify Sedentary Time and Physical Activity from Hip and Non-Dominant and Dominant Wrists in Older Adults

Author:

Migueles Jairo H.ORCID,Cadenas-Sanchez CristinaORCID,Alcantara Juan M. A.ORCID,Leal-Martín JavierORCID,Mañas AsierORCID,Ara IgnacioORCID,Glynn Nancy W.ORCID,Shiroma Eric J.

Abstract

Accelerometers’ accuracy for sedentary time (ST) and moderate-to-vigorous physical activity (MVPA) classification depends on accelerometer placement, data processing, activities, and sample characteristics. As intensities differ by age, this study sought to determine intensity cut-points at various wear locations people more than 70 years old. Data from 59 older adults were used for calibration and from 21 independent participants for cross-validation purposes. Participants wore accelerometers on their hip and wrists while performing activities and having their energy expenditure measured with portable calorimetry. ST and MVPA were defined as ≤1.5 metabolic equivalents (METs) and ≥3 METs (1 MET = 2.8 mL/kg/min), respectively. Receiver operator characteristic (ROC) analyses showed fair-to-good accuracy (area under the curve [AUC] = 0.62–0.89). ST cut-points were 7 mg (cross-validation: sensitivity = 0.88, specificity = 0.80) and 1 count/5 s (cross-validation: sensitivity = 0.91, specificity = 0.96) for the hip; 18 mg (cross-validation: sensitivity = 0.86, specificity = 0.86) and 102 counts/5 s (cross-validation: sensitivity = 0.91, specificity = 0.92) for the non-dominant wrist; and 22 mg and 175 counts/5 s (not cross-validated) for the dominant wrist. MVPA cut-points were 14 mg (cross-validation: sensitivity = 0.70, specificity = 0.99) and 54 count/5 s (cross-validation: sensitivity = 1.00, specificity = 0.96) for the hip; 60 mg (cross-validation: sensitivity = 0.83, specificity = 0.99) and 182 counts/5 s (cross-validation: sensitivity = 1.00, specificity = 0.89) for the non-dominant wrist; and 64 mg and 268 counts/5 s (not cross-validated) for the dominant wrist. These cut-points can classify ST and MVPA in older adults from hip- and wrist-worn accelerometers.

Funder

University of Pittsburgh

National Institute on Aging

Biomedical Research Networking Center on Frailty and Healthy Aging

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3