The Changes in Size of Periapical Lesions after Root Canal Treatments Assessed by Digital Periapical Radiography and Cone-Beam Computed Tomography: A 2-Years Prospective Clinical Study

Author:

Gudac Jelena,Hellén-Halme KristinaORCID,Maciulskiene VitaORCID

Abstract

Background and Objectives: There is limited information regarding comparison of long-term dynamics of periapical bone destruction estimated by digital periapical radiography (DPR) and by cone-beam computed tomography (CBCT). This study aimed to compare the radiographically assessed periapical changes of endodontically treated teeth over 2 years of follow-up and to analyse disagreements in periapical lesion size estimates around the same roots using DPR and CBCT. Materials and Methods: A total of 176 endodontically treated teeth, of 128 patients with apical periodontitis, were assessed by DPR and CBCT, at baseline and after 2 years. All periapical radiolucencies were categorised by severity (S0, S1, S2, S3) concerning their size. Descriptive statistics were used to report distribution of the radiolucencies at baseline and at follow-up, and their size transitions over 2 years. Site-specific comparison of the radiolucencies identified by two methods was performed using Z test and Pearson’s chi-square test. Results: majority of the detected radiolucencies were scored as S0: 65% and 68% at baseline; 89% and 83% at follow-up, by DPR and CBCT, respectively. Site-specific score comparison showed that disagreements comprised 18% and 20% of the total number of radiolucencies detected by DPR and CBCT, respectively. There were more disagreements between DPR and CBCT within categories S1 and S2 + S3 compared to S0: at baseline, they comprised 17–33% and after two years 62–95% of all detected radiolucencies within the category. 65% of non-matching score transitions over two years occurred between S0 and S1. The CBCT-based evaluation resulted in negative treatment outcomes for 10 more root canals than the DPR-based result. Conclusions: Most remarkable disagreement between DPR and CBCT recordings was observed within the radiolucency categories S2 and S3. However, the diagnostic accuracy of both radiographic methods was questionable as it resulted in a high proportion of non-matching S0-S1 lesion transitions over 2 years.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3