Diagnostic Accuracy of Coronary Angiography-Based Vessel Fractional Flow Reserve (vFFR) Virtual Stenting

Author:

Tomaniak Mariusz,Neleman Tara,Ziedses des Plantes Anniek,Masdjedi Kaneshka,van Zandvoort Laurens J. C.,Kochman Janusz,den Dekker Wijnand K.,Wilschut Jeroen M.,Diletti Roberto,Kardys Isabella,Zijlstra Felix,Van Mieghem Nicolas M.,Daemen Joost

Abstract

3D coronary angiography-based vessel fractional flow reserve (vFFR) proved to be an accurate diagnostic alternative to invasively measured pressure wire based fractional flow reserve (FFR). The ability to compute post-PCI vFFR using pre-PCI vFFR virtual stent analysis is unknown. We aimed to assess the feasibility and diagnostic accuracy of pre-PCI vFFR virtual stenting analysis (residual vFFR) with post-PCI FFR as a reference. This is an observational, single-center retrospective cohort study including consecutive patients from the FFR-SEARCH registry. We blindly calculated residual vFFR from pre-PCI angiograms and compared them to invasive pressure-wire based post-PCI FFR. Inclusion criteria involved presentation with either stable or unstable angina or non-ST elevation myocardial infarction (NSTEMI), ≥1 significant stenosis in one of the epicardial coronary arteries (percentage diameter stenosis of >70% by QCA or hemodynamically relevant stenosis with FFR ≤0.80) and pre procedural angiograms eligible for vFFR analysis. Exclusion criteria comprised patients with ST elevation myocardial infarction (STEMI), coronary bypass grafts, cardiogenic shock or severe hemodynamic instability. Eighty-one pre-PCI residual vFFR measurements were compared to post-PCI FFR and post-PCI vFFR measurements. Mean residual vFFR was 0.91 ± 0.06, mean post-PCI FFR 0.91 ± 0.06 and mean post-PCI vFFR was 0.92 ± 0.05. Residual vFFR showed a high linear correlation (r = 0.84) and good agreement (mean difference (95% confidence interval): 0.005 (−0.002–0.012)) with post-PCI FFR, as well as with post-PCI-vFFR (r = 0.77, mean difference −0.007 (−0.015–0.0003)). Residual vFFR showed good accuracy in the identification of lesions with post-PCI FFR < 0.90 (sensitivity 94%, specificity 71%, area under the curve (AUC) 0.93 (95% CI: 0.86–0.99), p < 0.001). Virtual stenting using vFFR provided an accurate estimation of post-PCI FFR and post-PCI vFFR. Further studies are needed to prospectively validate a vFFR-guided PCI strategy.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3