Abstract
This paper presents a 12-b successive approximation register (SAR) analog-to-digital converter (ADC) for biopotential sensing applications. To reduce the digital-to-analog converter (DAC) switching energy of the high-resolution ADC, we combine merged-capacitor-switching (MCS) and detect-and-skip (DAS) methods, successfully embedded in the subranging structure. The proposed method saves 96.7% of switching energy compared to the conventional method. Without an extra burden on the realization of the calibration circuit, we achieve mismatch calibration by reusing the on-chip DAC. The mismatch data are processed in the digital domain to compensate for the nonlinearity caused by the DAC mismatch. The ADC is realized using a 0.18 μm CMOS process with a core area of 0.7 mm2. At the sampling rate fS = 9 kS/s, the ADC achieves a signal-to-noise ratio and distortion (SINAD) of 67.4 dB. The proposed calibration technique improves the spurious-free dynamic range (SFDR) by 7.2 dB, resulting in 73.5 dB. At an increased fS = 200 kS/s, the ADC achieves a SINAD of 65.9 dB and an SFDR of 68.8 dB with a figure-of-merit (FoM) of 13.2 fJ/conversion-step.
Funder
National Research Foundation of Korea
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献