A 12-b Subranging SAR ADC Using Detect-and-Skip Switching and Mismatch Calibration for Biopotential Sensing Applications

Author:

Nguyen Cong Luong,Phan Huu Nhan,Lee Jong-WookORCID

Abstract

This paper presents a 12-b successive approximation register (SAR) analog-to-digital converter (ADC) for biopotential sensing applications. To reduce the digital-to-analog converter (DAC) switching energy of the high-resolution ADC, we combine merged-capacitor-switching (MCS) and detect-and-skip (DAS) methods, successfully embedded in the subranging structure. The proposed method saves 96.7% of switching energy compared to the conventional method. Without an extra burden on the realization of the calibration circuit, we achieve mismatch calibration by reusing the on-chip DAC. The mismatch data are processed in the digital domain to compensate for the nonlinearity caused by the DAC mismatch. The ADC is realized using a 0.18 μm CMOS process with a core area of 0.7 mm2. At the sampling rate fS = 9 kS/s, the ADC achieves a signal-to-noise ratio and distortion (SINAD) of 67.4 dB. The proposed calibration technique improves the spurious-free dynamic range (SFDR) by 7.2 dB, resulting in 73.5 dB. At an increased fS = 200 kS/s, the ADC achieves a SINAD of 65.9 dB and an SFDR of 68.8 dB with a figure-of-merit (FoM) of 13.2 fJ/conversion-step.

Funder

National Research Foundation of Korea

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3