Estimating Limits of Detection and Quantification of Ibuprofen by TLC-Densitometry at Different Chromatographic Conditions

Author:

Jampilek JosefORCID,Dolowy MalgorzataORCID,Pyka-Pajak AlinaORCID

Abstract

Ibuprofen is one of the best-known nonsteroidal anti-inflammatory and analgesic drugs. Following the previous work, the current study is focused on estimating the effect of different chromatographic conditions on the sensitivity of thin-layer chromatography in combination with UV densitometry, i.e., the detection and quantification of ibuprofen in a wide range of its concentrations including the lowest limits of detection (LOD) and quantification (LOQ). For this purpose, a reliable and easy-to-use calculation procedure for LOD and LOQ determination is presented in this work. In addition, the impact of type plates and mobile phase composition on the LOD and LOQ, respectively, of this active substance is accurately described. The results of detection and the quantification level of ibuprofen obtained under applied chromatographic conditions confirmed the utility of silica gel plates as well as silica gel bonded phases (i.e., reversed-phase (RP) plates) in the thin-layer chromatography (TLC)-densitometric analysis of ibuprofen at a low level, i.e., from several nanograms (below one microgram) to a few micrograms/spot. Among all chromatographic systems tested, the best are those consisting of silica gel 60F254 plates with concentrating zone (1.05583) and the mixture of n-hexane:ethyl acetate:glacial acetic acid in ratio 36:12:2 (v/v/v) as well as RP plates, i.e., RP-18F254 aluminum plates developed with methanol:water in volume composition 40:10 (v/v). These chromatographic systems allowed quantifying ibuprofen in the amount of 0.229 µg/spot and 0.228 µg/spot, which is less than 1 µg/spot. It can be stated that different chromatographic systems in combination with UV densitometric scanning at 224 nm proposed in this work can be successfully applied for the cost-effective and sensitive determination of ibuprofen as a widely used drug component as well as a residual in domestic wastewater. It was found that the modification of silica gel as well as the layer thickness of unmodified or modified silica gel 60 can influence the quality of chromatograms and the detection/quantification of ibuprofen in both normal phase (NP) and RP systems. Therefore, to obtain the best possible LOD and LOQ values of ibuprofen with precoated layers, suitable mobile phase and chromatographic plates are required.

Funder

Slovak Research and Development Agency

Publisher

MDPI AG

Subject

Process Chemistry and Technology,Chemical Engineering (miscellaneous),Bioengineering

Reference23 articles.

1. Chemical Compounds;Schlager,2006

2. Ibuprofen: Pharmacology, Therapeutics and Side Effects;Rainsford,2012

3. Mutschler Pharmacology and Toxicology;Mutschler,2010

4. Pharmacology and clinical action of COX-2 selective NSAIDs;Bovill,2003

5. Comparative utilization of visual, potentiometric titrations and UV spectrophotometric methods in the determination of ibuprofen;Ebeshi;Afr. J. Pharm. Pharmacol.,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3