Breast Density Evaluation According to BI-RADS 5th Edition on Digital Breast Tomosynthesis: AI Automated Assessment Versus Human Visual Assessment

Author:

Tari Daniele Ugo1ORCID,Santonastaso Rosalinda2ORCID,De Lucia Davide Raffaele1ORCID,Santarsiere Marika1,Pinto Fabio3

Affiliation:

1. Department of Diagnostic Senology District 12, Palazzo della Salute, Caserta Local Health Authority, 81100 Caserta, Italy

2. Department of Economics, University of Campania “L. Vanvitelli”, 81043 Capua, Italy

3. Department of Radiology, “A. Guerriero” Hospital, Caserta Local Health Authority, 81025 Marcianise, Italy

Abstract

Background: The assessment of breast density is one of the main goals of radiologists because the masking effect of dense fibroglandular tissue may affect the mammographic identification of lesions. The BI-RADS 5th Edition has revised the mammographic breast density categories, focusing on a qualitative evaluation rather than a quantitative one. Our purpose is to compare the concordance of the automatic classification of breast density with the visual assessment according to the latest available classification. Methods: A sample of 1075 digital breast tomosynthesis images from women aged between 40 and 86 years (58 ± 7.1) was retrospectively analyzed by three independent readers according to the BI-RADS 5th Edition. Automated breast density assessment was performed on digital breast tomosynthesis images with the Quantra software version 2.2.3. Interobserver agreement was assessed with kappa statistics. The distributions of breast density categories were compared and correlated with age. Results: The agreement on breast density categories was substantial to almost perfect between radiologists (κ = 0.63–0.83), moderate to substantial between radiologists and the Quantra software (κ = 0.44–0.78), and the consensus of radiologists and the Quantra software (κ = 0.60–0.77). Comparing the assessment for dense and non-dense breasts, the agreement was almost perfect in the screening age range without a statistically significant difference between concordant and discordant cases when compared by age. Conclusions: The categorization proposed by the Quantra software has shown a good agreement with the radiological evaluations, even though it did not completely reflect the visual assessment. Thus, clinical decisions regarding supplemental screening should be based on the radiologist’s perceived masking effect rather than the data produced exclusively by the Quantra software.

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3