Management of Malpositioned Double-Lumen Tubes: A Simulation-Based Training Exercise for Anesthesiology Residents

Author:

Hierlmeier BryanORCID,Prem Anand,Anand Suwarna,Lerant Anna,Ostrovsky GalinaORCID

Abstract

Objectives: Demonstrate the feasibility and effectiveness of using the AirSim® Bronchi airway simulator to teach anesthesia residents how to successfully troubleshoot and manage malpositioned double-lumen endotracheal tubes used for single-lung ventilation. Design: Prospective observational study. Setting: Simulation lab in a university-based anesthesiology residency training program. Participants: CA1 (PGY2) anesthesiology residents. Interventions: Each resident was initially tasked with troubleshooting a malpositioned double-lumen tube (DLT) on an AirSim® Bronchi (Trucorp, Craigavon, UK) airway simulator in one of the three positions and was timed on their performance. This first simulation was followed by completion of a survey that assessed the resident’s level of confidence in repositioning a malpositioned DLT. Following the initial simulation, a didactic presentation was given to the residents on the management of malpositioned DLTs using a protocol, followed by a practice session. Two months later, each resident repeated the simulation exercise. A follow-up survey was conducted after each simulation, assessing the quality of the curriculum and subsequent level of confidence in performing the same tasks using a five-point Likert scale. Measurements and Main Results: Ten residents at the University of Mississippi Medical Center completed the simulation exercises and curriculum. The average time it took to troubleshoot the malpositioned DLT during the first simulation was 139 s, with only 30% of the residents correctly identifying the specific malposition and 40% correctly repositioning the DLT after initial malposition. The repeat simulation after two months showed significant improvement in efficiency, with the average time to complete the task decreasing from 139 s to 56 s. During the second simulation exercise, all 10 residents were able to correctly identify the DLT malposition and correctly reposition the DLT to the correct position. Additionally, residents’ confidence levels in managing a malpositioned DLT improved significantly. Initially, 70% of the residents reported a lack of confidence in identifying and correcting a malpositioned DLT, but after the didactic curriculum and simulation training, 100% of the residents reported confidence in completing the task. Conclusions: The AirSim® Bronchi (Trucorp, Craigavon, UK) simulator can be used to effectively teach and evaluate residents on correctly identifying and repositioning a malpositioned DLT. The residents’ performance and level of confidence were evaluated before and after the simulation curriculum. The results reveal that simulation-based training is an effective educational tool for improving clinical performance and confidence in identifying and appropriately managing a malpositioned DLT.

Publisher

MDPI AG

Reference12 articles.

1. Simulation training and skill assessment in anesthesiology;Rothkrug,2021

2. Simulation for Learning and Teaching Procedural Skills

3. Double Lumen Endobronchial Tubes;Bora,2021

4. Lung Isolation Anesthesia;Smith,2021

5. Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3