Incidental Indeterminate Renal Lesions: Distinguishing Non-Enhancing from Potential Enhancing Renal Lesions Using Iodine Quantification on Portal Venous Dual-Layer Spectral CT

Author:

van der Star Simone1,de Jong Pim A.1,Kok Madeleine1

Affiliation:

1. Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, 3584 CX Utrecht, The Netherlands

Abstract

The purpose of our study is to determine a threshold for iodine quantification to distinguish definitely non-enhancing benign renal lesions from potential enhancing masses on portal venous dual-layer spectral computed tomography (CT) to reduce the need for additional multiphase CT. In this single-center retrospective study, patients (≥18 years) scanned between April 2021 and January 2023 following the local renal CT protocol were included. Exclusion criteria were patients without renal lesions, lesions smaller than 10 mm, only fat-containing lesions, abscesses or infarction, follow-up after radiofrequent ablation, wrong scan protocol, or artefacts. Scans were performed on a dual layer detector-based spectral CT (CT 7500, Philips Healthcare, Best, The Netherlands). Iodine concentration (mgI/mL) in renal lesions was determined using spectral data. Analyses were performed for all lesions and for lesions of >30 HU on portal venous CT. Enhancement on multiphase CT (≥20 ΔHU from true unenhanced (TUE) to portal venous phase (PVP) CT) was used as reference standard. To determine thresholds for iodine concentration receiver operating characteristic (ROC) curves, area under the curve (AUC) and 95% confidence intervals were calculated. To obtain thresholds for definite (non-)enhancement, 100% sensitivity with maximum specificity and 100% specificity with maximum sensitivity were noted. Data were measured using one reader. To assess interobserver agreement, a second reader performed measurements on the PVP CT scans. A total of 103 patients (62 years ± 14, 68 men) were included. We measured 328 renal lesions, 56 enhancing lesions (17%) in 38 patients and 272 non-enhancing lesions (83%) in 86 patients. The threshold for non-enhancing lesions was 0.76 mgI/mL or lower (100% sensitivity, 76% specificity). The threshold for a definite enhancing mass was 1.69 mgI/mL or higher (100% specificity, 78% sensitivity). A total of 77% of indeterminate lesions (>30 HU on PVP CT) in our study could be definitely characterized. Renal lesions can be definitively classified as non-enhancing or enhancing on PVP spectral CT using thresholds of 0.76 mgI/mL or 1.69 mgI/mL, respectively, eliminating the need for multiphase imaging.

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3