Minimally Invasive Plate Osteosynthesis (MIPO) of Comminuted Radial Fractures Using a Locking Plate Contoured on a 3D-Printed Model of the Feline Antebrachium: A Cadaveric Study

Author:

Trębacz Piotr1ORCID,Frymus Jan1ORCID,Pawlik Mateusz23ORCID,Barteczko Anna2,Kurkowska Aleksandra23,Czopowicz Michał4ORCID

Affiliation:

1. Department of Surgery and Anaesthesiology of Small Animals, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, Nowoursynowska 159 C, 02-776 Warsaw, Poland

2. CABIOMEDE Ltd., Karola Olszewskiego 21, 25-663 Kielce, Poland

3. Department of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Roosevelta 40, 41-800 Zabrze, Poland

4. Division of Veterinary Epidemiology and Economics, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, Nowoursynowska 159 C, 02-776 Warsaw, Poland

Abstract

(1) Background: Due to the unique structural and functional characteristics of the forelimb in cats, fractures of the radius and ulna are best repaired using internal fixation and stabilization in accordance with AO principles. This study presents the results of reduction of 42 cadaveric comminuted feline radial fractures reduced by minimally invasive plate osteosynthesis (MIPO). (2) Methods: Radius fractures were created on 21 pairs of forelimbs with intact bones. MIPO was then performed using two locking bone plates pre-contoured on 3D-printed bone models of the antebrachium of a male and a female cat. Pre- and postoperative radiographs were taken, and radius length and anatomical lateral distal radial angle (aLDRA) were measured. (3) Results: All fractures were classified as complex diaphyseal fractures of the radius. The radial bone length did not change significantly after surgery (F1,18 = 0.01, p = 0.933). However, the aLDRA was modified after surgery (F1,18 = 7.51, p = 0.013), but this change was only observed in females, in whom the aLDRA was significantly reduced (p = 0.035) compared to the value determined by the shape of the plate. In males, the pre- and postoperative aLDRA values were similar (p = 0.824). In 40 cases, alignment, adjacency of bone fragments, and apparatus were judged to be satisfactory. In two cases, the plate was fixed to the proximal radius and distal ulna due to misidentification of the distal radius. In both cases, revision surgery and correct fixation of the radius gave proper alignment, adjacency, and apparatus. (4) Conclusion: A pre-contoured plate on a 3D-printed model of the male and female domestic cat antebrachium was suitable for the reduction and stabilization of comminuted radial fractures in a cohort of domestic cat cadavers without the need to print individual antebrachial bone models for each patient.

Publisher

MDPI AG

Reference34 articles.

1. Treatments for feline long bone fractures;Harari;Vet. Clin. North. Am. Small Anim. Pract.,2002

2. Incidence of and predisposing factors for nonunion of fractures involving the appendicular skeleton in cats: 18 cases (1998–2002);Nolte;J. Am. Vet. Med. Assoc.,2005

3. Long bone fractures in cats: A retrospective study;Cardoso;Vet. Zootec.,2016

4. Feline diaphyseal fractures: Management and treatment options;Zurita;J. Feline Med. Surg.,2022

5. Thakur, A.J. (2020). The Elements of Fracture Fixation, Elsevier. [4th ed.].

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3