Accuracy of Implant Casts Generated with Conventional and Digital Impressions—An In Vitro Study

Author:

Ribeiro Paulo,Herrero-Climent Mariano,Díaz-Castro Carmen,Ríos-Santos José Vicente,Padrós Roberto,Mur Javier Gil,Falcão Carlos

Abstract

Purpose: The aim of this study was to compare the accuracy of digital dental impressions with the accuracy of impressions obtained via conventional techniques. Methods: Two different master models were created, one with parallel implants (model 1) and the other with non-parallel implants (model 2). These reference master models included 4 Klockner KL RP implants (Klockner Implant System SA, Barcelona, Spain), which were juxta-placed and equidistant in the intermentoneal region. In model 1 the implants were placed parallel to each other, whereas in model 2 the implants were placed such that there was a divergence angle of 15° between the more distal implants, and a convergence angle of 15° between the two central implants. A total of four types of impressions were obtained from model 1 (four groups, n = 10 each), including closed tray impressions with replacement abutments; open tray impression groups for dragging copings, without splinting; open tray impressions for ferrules; and impressions obtained using the 3MTM True Definition Scanner system. For model 2 three groups were created (three groups, n = 10 each), including closed tray impressions with replacement abutments; open tray impression for dragging copings, without splinting; and impressions obtained using the 3MTM True Definition Scanner system. The master models and the models obtained using conventional methods were digitalized in order to compare them via an extraoral high-resolution scanner (Imetric IScan D104i, Porretruy, Switzerland). The STL (Stereo Lithography (format for transferring 3 dimensional shape information)) digital values were loaded into reverse-engineering software and superimposed with their respective STL master models in order to evaluate deviations in three dimensions. We then analyzed the squares of the deviations in the three axes and evaluated the median and the sum of the deviation square. Statistical analysis was performed using the IBM Corp. Released 2016. IBM SPSS Statistics for Windows, Version 24.0. Armonk, NY: IBM Corp. The normality of the distributions was analyzed according to a Kolmogorov-Smirnov test. The median comparison was performed using the differences between the medians, analyzed using non-parametric Kruskal-Wallis and Mann-Whitney tests with a significance level of p < 0.05. Results: For model 1, the deviations of the digital impressions were smaller than those associated with the conventional techniques. The sum value in group D was 1,068,292, which was significantly lower than those of groups A, B, and C, which were shown to be 2,114,342, 2,165,491, and 1,265,918, respectively. This improvement was not observed when using model 2, however, where the conventional techniques yielded similar results. Group F simultaneously presented the lowest total square sum of the three deviations (1,257,835), indicating a significantly higher accuracy for this group in model 2, while the sum values were 1,660,975 and 1,489,328 for groups E and G, respectively. Conclusion: Digital impressions of full-arch models were able to achieve the accuracy of conventional impressions in an in vitro model. Nevertheless, further in vivo studies are needed to validate these in vitro results.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3