Abstract
Low melting point thermal energy storage (TES) materials have been proposed in the last years to reduce the storage cost in concentrating solar power (CSP) technology. One of the most interesting additive due to the enhancement in thermal properties is lithium nitrate. However, there is a lack of dynamic corrosion tests to simulate real operation conditions in CSP plants. In this work, we present a dynamic reactor set up where a mixture of 30 wt.% LiNO3 + 57 wt.% KNO3 + 13 wt.%. NaNO3 is moved through a mechanical stirrer obtaining a lineal speed of 0.30 m/s. A commercial carbon steel A516 was tested as container material at 390 °C during 1000 h. Fe2O3 and Fe3O4 were obtained as the main corrosion products by scanning electron microscopy (SEM) and x-ray diffraction (XRD) with a metallographic corrosion rate of 0.015 mm/year.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献