Comparison of Two Methods for the Measurement of Blood Plasma and Capillary Blood Glucose in Tropical Highland Grassing Dairy Cows

Author:

López Catalina1ORCID,Hincapié Valentina1,Carmona Jorge U.2ORCID

Affiliation:

1. Grupo de Investigación Patología Clínica Veterinaria, Departamento de Salud Animal, Universidad de Caldas, Calle 65 No 26-10, Manizales 170004, Colombia

2. Grupo de Investigación Terapia Regenerativa, Departamento de Salud Animal, Universidad de Caldas, Calle 65 No 26-10, Manizales 170004, Colombia

Abstract

(1) Background: There is lack of published studies validating specific cow-side glucometers such as Centrivet GK (CVGK). (2) Methods: The aims were (1) to measure and compare the blood glucose concentrations in 52 tropic highland grassing cows by using CVGK and the traditional enzymatic/photometric assay (EPA) in plasma and serum (reference method) and (2) to establish if glucose concentrations obtained via these methods could be affected by several demographic and zootechnical parameters of the dairy herd evaluated. (3) Results: Glucose concentrations were significantly (p = 0.00) affected by the method used for their measurement. The intra-assay coefficient of variation (CV) for glucose concentrations in plasma EPA and for CVGK was 14% for both methods with serum EPA, whereas the inter-assay CV for plasma EPA and CVGK was 8% and 13.7%, respectively, with serum EPA. Pearson correlation coefficient calculations between the reference method in serum and plasma presented a slightly positive significant (p = <0.000) correlation (r = 0.56), whereas there was not a significant (p = 0.413) correlation between serum EPA and CVGK (r = 0.135). The Passing and Bablok regressions were out of the ideal expected values for the slope (β = 1) and the intercept (α = 0) (11), whereas the Bland–Altman plots showed a bias of 5.29 ± 11.73 (mg/dL) for serum and plasma and 11.01 ± 15.74 (mg/dL) for serum and CVGK. The ROC curve showed no sensitivity in detecting normoglycemic cows (area = 53.7 %, e.d = 12.5 %, p = 0.759) for CVGK when compared to plasma EPA (area = 36.1 %, e.d = 14.2 %, p = 0.256). Plasma EPA exhibited a better but not significant effect in detecting hyperglycemic cows (area = 63.9%, e.d = 14.2%, p = 0.256) when compared to HHD (area = 46.3 %, e.d = 12.5 %, p = 0.759). General glucose concentrations, independently of the method used, were significantly (p = <0.001) greater in young cows when compared to adult and old cows. (4) Conclusions: Glucose concentration measurement in plasma by using EPA or in capillary blood via CVGK were not reliable methods when compared with the reference method.

Funder

Universidad de Caldas, Manizales, Colombia

Publisher

MDPI AG

Subject

General Veterinary,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3